The Goodman® 2006 AEPF Multi-Position, Variable-Speed Air Handler is suitable for use with refrigerant R-22. The Air Handlers’ blower design includes a variable-speed DC motor to help eliminate the cold blast of air upon heating start-up.

Standard Features

  • Check flowrater expansion device for cooling and heat pump applications
  • Variable-speed motor
  • Provides constant CFM over a wide range of static pressure conditions independent of duct system; provides low CFM for efficient fan-only operation
  • Up to 14 field-selectable airflow settings can be adjusted to optimize the system’s CFM for each individual mode of operation
  • Improved humidity control and comfort
  • Compatible with heat pumps and variable-capacity cooling applications
  • Multi-position—upflow, downflow or horizontal installations
  • Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections
  • 5 kW to 21 kW electric heat kit available as a field-installed option

Cabinet Features

  • Fully painted cabinet with attractive Architectural Gray finish
  • Built-in filter rack for 1” filter (filter not included)
  • Low-voltage cabinet connections; control circuit is arranged to permit staging
  • Power supply on top; low-voltage entry on top or side
  • Factory-sealed to achieve 2% or less leakage rate at 1.0” water gauge external duct static pressure

Blower Cooling Capacity

The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

Blower Cooling Capacity
2.5 Tons
CFM (Low/High)
1200 / 600 CFM
Electric Heat Capabilities (Optional)

One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

Electric Heat Capabilities (Optional)
10 / 5 / 8 Kilowatts
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
15 Amps
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
3/4 Inches
Shipping Weight
147 lbs
19 1/2 Inches
22 Inches
46 3/4 Inches
208 / 230 / 240 Volts
Parts Warranty
5 Years