(800)865-5931 Monday to Friday 8:30 AM - 5:00 PM Central
0
Free Shipping See Details
|
No Sales Tax See Details

Friedrich M33TYF

33,000 BTU Cooling (2.75 Ton), 37,900 BTU Heating, 15 SEER Heating / Cooling (Heat Pump), Three-Zone Mini-Split System, 220 Volts, R-410A Refrigerant

(1 Review)

Services

  • Flat Rate Returns $30
  • Pro Installation
  • Liftgate Delivery $25
  • Shipping to Canada
    SHIPPING TO CANADA

    Canadian tax and shipping fees may be estimated prior to purchasing an item by completing the form below.

    TAXES
    Duties (%): N/A
    Canada Tax (%): N/A
    Brokerage: N/A
    Total taxes: N/A
    Quantity: Postal Code: Calculate Shipping

Friedrich Air multi-zone mini-split systems can be installed in a dual, or tri-zone configuration.  Featuring advanced inverter technology, Friedrich mini-split systems let you reach the desired temperature faster, maintain it more accurately, and reduce energy costs.  The inverter technology allows each system to adjust capacity and cooling output to provide only the amount of cooling needed at a given time.  For example, a 1.5 ton system will operate even more efficiently as a 1.25 ton system if that is all that is needed.

(Note: These heat pumps will not operate in heating mode when the outdoor temperature is below 14°F.  The heating capacity at an outdoor temperature of 47°F is 13,600 BTU in the larger zones and 10,700 BTU in the smaller zone, while heating capacity at an outdoor temperature of 17°F is only 9,200 BTU in the larger zones and 7,200 BTU in the smaller zone.)

Standard Features:

  • Auto swing louvers (up / down)
  • Continuous 'Air Sweep'
  • Auto-restart after power interruptions
  • Auto-shut flaps close when unit is off for a sleeker appearance
  • Washable, reusable air filters
  • Removable front grille
  • Auto-changeover (heat pump models)
  • Low-ambient operation
  • 24-hour timer and sleep timer
  • Auto / cool / dry / fan / heat modes
  • Four fan speeds: high / medium / low / quiet, plus auto-fan
  • Remote control holder
  • Unique transmitter codes to prevent unintentional interference with other units when using remote control

System Components:

  • 1 MR36TQY3F 36,000 BTU Outdoor Heat Pump
  • 1 MW09Y3FM 9,500 BTU Indoor Air Handler
  • 2 MW12Y3FM 12,000 BTU Indoor Air Handlers
  • 3 Remote Controls

Complete your system by selecting three line sets from the Accessories tab above.  Line sets come in 15 foot, 35 foot, and 50 foot lengths.

Total Cooling Capacity

The total amount of cooling delivered by the system. This number is inclusive of all interior air handlers.

Total Cooling Capacity
33,000 BTU
Total Cooling Capacity
2.75 Ton(s)
Tons per Zone

The amount of cooling delivered into the space by each air handler rated in tons.

Tons per Zone
.78 , .98
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
37,900 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
15 SEER
Energy Efficiency Ratio

The measure of air conditioner efficiency at its maximum load

Energy Efficiency Ratio
8.8 EER
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
9.0 HSPF
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Moisture Removal

The amount of water that can be removed from the air rated in pints per hour.

Moisture Removal
2.9 , 3.7 Pts/Hr
Factory Precharge

This unit is charged with enough refrigerant for the condensing unit evaporator coil and the length of line stated. Longer line sets can be used but would require some additional refrigerant for appropriate operation.

Factory Precharge
165 Feet
Minimum Ampacity
22.5 Amps
Maximum Fuse/Breaker

The maximum capacity breaker that the unit can be connected to (This is the best option for consistent performance)

Maximum Fuse/Breaker
30 Amps
Wiring Requirement for Indoor Unit

The wiring recommended to connect the outdoor unit to the interior air handler.

Wiring Requirement for Indoor Unit
3 Conductor/ 14 Guage and a ground per head
Maximum Line Length

The maximum length of line set approved for use with this product.

Maximum Line Length
82 Feet
Maximum Height Difference

The maximum vertical distance between the condensing unit and the air handler.

Maximum Height Difference
49 Feet
Line Set Connection Type

There are two main types of connections for HVAC products brazed and flared. Brazed connections are typically used in standard split systems, and flare connections are typically used on mini splits and can be connected using a wrench.

Line Set Connection Type
Flare
ENERGY STAR® Qualified

Products earn the ENERGY STAR label by meeting the energy efficiency requirements set forth in ENERGY STAR specifications. The EPA establishes these specifications based on the following set of principles:

  • Product categories must contribute significant energy savings nationwide.
  • Qualified products must deliver the features and performance demanded by consumers, in addition to increased energy efficiency.
  • If the qualified product costs more than a conventional, less-efficient counterpart, purchasers will recover their investment in increased energy efficiency through utility bill savings, within a reasonable period of time.
  • Energy efficiency can be achieved through broadly available, non-proprietary technologies offered by multiple manufacturers.
  • Product energy consumption and performance can be measured and verified with testing.
  • Labeling would effectively differentiate products and be visible for purchasers.

ENERGY STAR® Qualified
No
Zones

The number of interior air handlers connected to the condensing unit. Typically one, two, or three zones.

Zones
3
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
1/4 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
3/8 Inches
Indoor Section Size, W x H x D
31 1/8 x 10 7/8 x 8 1/2 Inches
Sound Rating, Indoor

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Sound Rating, Indoor
27 / 29 / 33 / 37 / 39 / 42 / 46 Decibels
Sound Rating, Outdoor

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Sound Rating, Outdoor
52 Decibels
Outdoor Section Size, W x H x D
35 3/8 x 32 5/8 x 13 Inches
Indoor Section Weight
21 Lbs
Outdoor Section Weight
159 Lbs
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
6 Years
Parts Warranty
2 Years

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.