Goodman DSZC160361
3 Ton, 16 SEER, Two-Stage Heat Pump, ComfortNET Communications System Compatible, R-410A Refrigerant

ON SALE!
$2,136.99
Compare to:$2,799.99
You save:$663.00
Installation Video Included

The Goodman® brand DSZC16 16 SEER Heat Pump uses the environmentally friendly refrigerant R-410A and features energy efficiencies and operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. The DSZC16 features the two-stage, high-efficiency Copeland® UltraTech scroll compressor, which provides improved temperature and humidity control.  This unit is designed for the consumer who desires superior comfort, quiet operation, and environmentally friendly air conditioning performance.

All Goodman 16 SEER heat pumps must be installed with a bi-flow thermostatic expansion valve. This valve is installed in front of the indoor evaporator coil inline with the line set piping.

When this unit is installed with the manufacturer recommended evaporator coil, a Goodman variable speed furnace, variable speed air handler or variable speed modular blower, it is usually 16 SEER. To achieve 16 SEER for a certainty, see Accessories tab above for actual products compatible with this heat pump, or the "Instructions & Brochures" tab above for Goodman's spec sheet details.

Need help putting a complete heat pump system together? Use our easy System Selector and we’ll do it for you!

If you are installing a heat pump with a backup heat source which will be a fuel furnace, you will need to install an electronic all fuel kit.  This kit switches between the two heat sources as needed and prevents both the heat pump and backup heat from running at the same time. Alternatively, you can install the Honeywell VisionPro 8000 (TH8320U1008) thermostat which has the all-fuel kit functionality built into it already, in which case an external all fuel kit would not be needed.

Please note that this heat pump equipment comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. Yes you can purchase this equipment without being EPA certified. If you are mechanically inclined you may perform about 90% of the equipment installation yourself. However we strongly recommend that a professional heating / cooling contractor do the final part of the installation, including the managing of refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this heat pump validates your warranty with Alpine.

Standard Features of this Heat Pump

  • Two-Stage Copeland® UltraTech scroll compressor
  • R-410A environmentally friendly refrigerant 
  • Copeland® ComfortAlert diagnostics
  • ComfortNet™ Communications System compatible
  • Two-Speed condenser fan motor
  • High-quality foam compressor sound blanket
  • Loss of charge switch
  • High-pressure switch
  • Factory-installed filter dryer
  • Copper tubing / enhanced aluminum fin coil
  • Sweat connection service valves with easy access to gauge ports
  • ARI Certified; ETL Listed

Cabinet Features

  • Wire fan discharge grille
  • Steel louver coil guard
  • Baked-on powder paint finish
  • Rust-resistant coated screws
  • Compact footprint
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When central air conditioner is properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

Cooling Capacity
36000 BTU 

Cooling Capacity
3 Tons 

Maximum Heating Output BTU
36000 BTU 

SEER
16 SEER 

Heating Seasonal Performance Factor
9.75 HSPF 

Refrigerant
R-410A  

Maximum Overcurrent Protection (Breaker)
35 Amps 

Compressor Type
Scroll UltraTech™  

Low Pressure Safety Switch
Yes  

Liquid Line Connection Size
3/8 Inches 

Suction Line Connection Size
7/8 Inches 

TXV Required
Yes  

Noise Level
73 Decibels 

Pad Size
36x36 Inches 

Shipping Weight
282 lbs 

Width
35 1/2 Inches 

Depth
35 1/2 Inches 

Height
38 1/4 Inches 

Voltage
208 / 230 Volts 

Frequency
60 Hz 

Voltage Phase
1  

Compressor Warranty
Lifetime With Online Registration  

Parts Warranty
10 Years 
Your Order
Ways to Order
See Order Status
Returns
Modify or Cancel Order
Missing Order Item
Damaged Shipments
Warranty Claims
Quotes
View Quotes
Request Custom Equipment
Technical Support
Learning Center
Instruction Manuals
Contact Technical Support
Policies
Shipping Policy
Return Policy
Scratch-N-Dent Policy
Volume Discount Policy
Privacy Policy
Website Terms of Use
Alpine
About Us
Customer Reviews
  Phone
(800) 865-5931
Monday to Friday
8:30am - 5:00pm Central
  Mailing Address
1002 22nd St.
Rockford, IL 61108
  Chicago Office
954 W Washington Blvd
Suite 500
Chicago, IL 60607
  Email
[email protected]
or Contact Us Here
  Fax
(425) 928-2455
© Copyright 2002-2014, Alpine Home Air Products. All Rights Reserved. A Todd Arthurs Company, Inc