Goodman GSH130601-DRY

5 Ton, 13 SEER Heat Pump, For R-22 Refrigerant Use (Unit is Uncharged)

(2 Reviews)

Services

  • Flat Rate Returns $30
  • Pro Installation
  • Liftgate Delivery $25
  • Shipping to Canada
    SHIPPING TO CANADA

    Canadian tax and shipping fees may be estimated prior to purchasing an item by completing the form below.

    TAXES
    Duties (%): N/A
    Canada Tax (%): N/A
    Brokerage: N/A
    Total taxes: N/A
    Quantity: Postal Code: Calculate Shipping

The Goodman® GSH13 13 SEER Heat Pump features an attractive louvered metal guard that protects the coil from damage and strengthens the unit. Designed for ground-level or rooftop mount, the base pan elevates the unit above the slab for excellent water drainage. A powder-paint finish provides premium durability and improved UV protection.

This heat pump requires an indoor air handler or evaporator coil as part of a complete system. The coil or air handler you should use depends on two factors about the condenser: the tonnage, and the efficiency rating ("SEER"). Usually, high efficiency condensers require a larger tonnage coil than the tonnage of the condenser. For example, a 2 ton 16 SEER condenser might be paired with a 3 ton evaporator coil. To find the specific coils and air handlers that are recommended by the manufacturer for this condenser, check the Accessories tab above. Also, you can view the manufacturer's specifications sheets at the Documents tab above.

Some models of the Goodman condensers include an orifice (also called "flow rater" or "piston") in a small bag taped to the side of the condenser. If the condenser you purchase includes this orifice, you will need to replace the orifice already inside the evaporator coil or air handler you purchase with this orifice included with the condenser. Doing so makes the condenser and evaporator coil compatible. You can view this step-by-step guide to see how to easily change the orifice.

If you are installing a heat pump with a backup heat source which will be a fuel furnace, you will need to install an electronic all fuel kit.  This kit switches between the two heat sources as needed and prevents both the heat pump and backup heat from running at the same time. Alternatively, you can install the Honeywell VisionPro 8000 (TH8320U 1008) thermostat which has the all-fuel kit functionality built in, in which case an external all-fuel kit would not be needed.

Need help putting a complete system together? Use our easy System Selector and we’ll do it for you!

Please note that this equipment uses liquid refrigerant and that by federal law you must be EPA certified to handle the refrigerant. You can purchase this equipment without being certified, and if you are mechanically inclined you can perform about 90% of the equipment installation yourself. However, you must have a professional heating/cooling contractor do the final part of the installation which requires managing the refrigerant.

For Tips for Selecting Matched Components and Line Sets click here.

Standard Features

  • Energy-efficient Copeland® compressor
  • Copper tube/aluminum fin coil
  • 850 RPM condenser fan motor
  • For use with R-22 refrigerant; charged with inert gas for shipping
  • Liquid refrigerant return protection
  • Factory-installed liquid line filter dryer
  • Low-pressure switch
  • Time-initiated, temperature-terminated defrost control
  • Brass liquid and suction service valves
  • Contactor with lug connection
  • Ground lug connection
  • ARI Certified
  • ETL Certified

Cabinet Features

  • Unique Goodman® sound control top design
  • Steel louver coil guard
  • Heavy-gauge, galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500- hour salt-spray
  • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
55,500 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
5 Tons
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
55,500 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
13 SEER
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
8.5 HSPF
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-22
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
50 Amps
Low Pressure Safety Switch

A safety switch, that when/if the pressure in the system gets too low, it will turn off the equipment to avoid damaging it.

Low Pressure Safety Switch
Yes
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
7/8 Inches
TXV Required

A TXV is an inline metering device used to regulate the amount of refrigerant entering the evaporator coil. They are frequently used in high efficiency systems.

TXV Required
Yes
Noise Level

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Noise Level
77 Decibels
Pad Size
36x36 Inches
Shipping Weight
266 lbs
Width
35 1/2 Inches
Depth
35 1/2 Inches
Height
34 3/4 Inches
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
5 Years
Parts Warranty
5 Years