The Haier HPCE 14 SEER packaged heat pump feature heavy gauge galvanized steel construction, environment friendly R-410A refrigerant, and a high efficiency compressor.  Haier packaged units sit on the ground or rooftop, outside your home or business, and deliver dependable, quiet, year-round heating and cooling comfort from a single, self-contained unit.  All units come fully charged with refrigerant from the factory.

Standard Features

  • R-410A chlorine-free refrigerant
  • High efficiency, high reliability compressor with an internal relief valve
  • Heavy gauge galvanized steel construction
  • Full perimeter base rails for easy installation
  • Multi-speed blower motor
  • High efficiency coils with louvered aluminum fins and rifled copper tubing
  • Convertible airflow - horizontal or downflow
  • Service ports accessible without removing access panels
  • Louvered air inlet panels for condenser coil protection
  • Electric heat kits up to 25 kW available as a field-installed option
  • 10 Year limited compressor warranty
  • 10 Year limited parts warranty

 


Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Downflow / Horizontal
Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
36000 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
3 Tons
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
36000 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
14 SEER
Electric Heat Capabilities (Optional)

One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

Electric Heat Capabilities (Optional)
10 / 15 / 5 / 8 Kilowatts
Energy Efficiency Ratio

The measure of air conditioner efficiency at its maximum load

Energy Efficiency Ratio
11.5 EER
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
8.0 HSPF
Nominal CFM

The amount of air that can be moved by the fan, measured in cubic feet per minute (cfm).

Nominal CFM
1200
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
45 Amps
Fuel Type
Electricity
Product Weight
441 lbs
Width
75 19/32 Inches
Depth
28 3/32 Inches
Height
42 Inches
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
10 Years
Parts Warranty
10 Years

DIGITAL THERMOSTATS
Product Image
Honeywell TH4210D1005

Pro 4000 Heat Pump Only Programmable Thermostat - Two Stage Heat One Stage Cool

$44.99 Qty:
Honeywell FocusPRO 6000
Honeywell TH6320U1000

FocusPro 6000 Universal Programmable Thermostat, 3 Stage Heat 2 Stage Cool (Large Display)

$82.99 Qty:
Honeywell VisionPRO 8000 TH8110R1008
Honeywell TH8320R1003

VisionPRO 8000 Programmable Touchscreen Thermostat, Three Stage Heat Two Stage Cool

$150.99 Qty:
Nest Thermostat 2
Nest Thermostat

Energy Saving, Learning Thermostat, 2nd Generation, T200477W

$249.99 Qty:
ELECTRICAL DISCONNECT
DiversiTech EDS-60U
Alpine AG-DCT

Safety Non-Fused Electrical Disconnect

$12.99 Qty:
ELECTRICAL WHIPS
Electrical Whip 4
Alpine AG-WHP8

3/4 x 48 Inches, #8 Gauge Electrical Whip

$15.99 Qty:
OUTDOOR PADS & BRACKETS
DiversiTech HPR-6
DiversiTech HPR-6 (4-Pack)

(4-Pack) 6" Heat Pump Risers

$10.99 Qty:



Get expert assistance from our team

Call our product specialists at 800-865-5931
Mon-Fri 7am-7pm, Sat 9am-2pm CT

Joseph
Brian
Peter
Dan
Matt
Russ

Or ask us here: