The Alpine AHPZ Packaged Terminal Air Conditioner (PTAC) is made by Chigo and includes a wall sleeve, grill, electric heater, and remote control.  PTAC units, like those found in a typical hotel room, are an ideal way to heat and air condition offices, apartments, dormitories, and residential additions. New PTAC units are designed with efficiency, durability, and quiet operation in mind. This PTAC is a heat pump with an electric heat strip.

When purchasing a PTAC unit be sure to match the power plug to the wall recepticle. View this plug chart which will show you what wall recepticle is required for the PTAC unit of your choice.

Features

  • Wall sleeve & grill included!
  • Remote control included!
  • LCDI power cord 
  • 3kW Electric heater
  • Continuous airflow in heat mode to improve air circulation 
  • Automatic 3-minute compressor lockout
  • Random restart delay
  • Indication LEDs
  • High pressure protection
  • Failure tolerance
  • Standard physical dimensions - Replacing older units is made easy
  • Weather protected electrical components
  • Highly featured microprocessor controls - Programmed to maximize comfort conditions
  • Permanently lubricated fan motors
  • Low / High indoor fan speeds
  • Rotary compressor - Smoother operation for quiet, dependable service and high efficiency
  • Indoor coil frost control
  • Automatic emergency heat - Automatically uses electric resistance heat if the heat pump output is insufficient to maintain selected room temperature
  • High temperature heat pump operation protection
  • 5 Year Parts Warranty

 

Quantity Pricing
Quantity Price Each
1-3 $ 766.99
4-10 $ 691.99
11-20 $ 661.99
21+ Call for quote

Electric Heater Capacity (BTUs)

1 kilowatt equals 3,400 BTUs of heat. Not sure how many BTUs you need? Try our Sizing Estimator.

Electric Heater Capacity (BTUs)
10,200 BTU
Heat Pump

The amount of heat, rated in BTUs, that the heat pump can deliver in the space.

Heat Pump
6,000 BTUs
Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
7,000 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
0.6 Tons
Energy Efficiency Ratio

The measure of air conditioner efficiency at its maximum load

Energy Efficiency Ratio
11.9 EER
Coefficiency of Performance

Coefficient of Performance is the efficiency ratio of the amount of heating or cooling provided by a heating or cooling unit to the energy consumed by the system. The higher the Coefficient of Performance the more efficient the system. Resistance electrical heating (such as electric baseboards) for example has a Coefficient of Performance of 1.0

Coefficiency of Performance
3.4 COP
Nominal CFM

The amount of air that can be moved by the fan, measured in cubic feet per minute (cfm).

Nominal CFM
268 / 337
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Dehumidifying Capacity

The amount of water vapor that can be removed from the air per hour. Measured in pints.

Dehumidifying Capacity
0.1 Pints / Hour
Reverse Heating Wattage

The amount of watts consumed per hour while operating in heat pump mode.

Reverse Heating Wattage
520 watts
Cooling Wattage

The amount of watts consumed per hour while operating in cooling mode.

Cooling Wattage
590 watts
Breaker Size

The maximum capacity breaker that the unit can be connected to (This is the best option for consistent performance)

Breaker Size
20 amps
Electric Heater Size

The amount of kilowatts (kw). The higher the kilowatt rating the higher the heating capacity.

Electric Heater Size
3 kilowatts
Compressor Type

Reciprocating compressors use a piston to compress the refrigerant.

Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

Compressor Type
Rotary
NEMA Plug

The appropriate power receptacle required for this unit.

NEMA Plug
6 - 20R
Cut-Out Dimensions, W x H

Th rough-in cut out dimension through your wall that you will place the unit into.

Cut-Out Dimensions, W x H
42 1/4 x 16 1/4 inches
Chassis Weight
120 lbs
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Parts Warranty
5 Years