The Goodman CAPF3030B6 (Item No. 606452) has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Monday - Friday

8:30 AM - 5:00 PM Central

This Goodman CAPF3030B6 has some cosmetic damage incurred during shipping. For detailed photos please click 'See Additional Images' above. This Goodman CAPF3030B6 meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman® CAPF Cased Upflow/Downflow Indoor Coils are made for split system air conditioners and heat pumps. The coil’s cabinet is painted Architectural Gray.

This coil can operate with a heat pump or condenser of two different tonnages, as noted in the product description above. The unit comes equipped with an orifice (flowrater) for the larger listed tonnage. If you wish to pair the coil with a condenser or heat pump of the smaller tonnage, an orifice in that tonnage will need to be used (unless a TXV is required instead). If you are purchasing a new Goodman heat pump or condenser, the required orifice can be found on our site by clicking the Accessories tab on the product page for that item. However, if you are purchasing this coil only and wish to pair it with equipment of the lower tonnage rating as listed on the description for this coil, you will need to separately purchase the smaller orifice and install it in the coil before operating. See this step-by-step guide to learn how to easily do so. Alternatively, instead of an orifice a thermostatic expansion valve (TXV) may be used or required for some equipment, such as 14 SEER and higher heat pumps and all equipment that uses R-410A refrigerant (see equipment spec sheets for details or call us for assistance).

For Tips for Selecting Matched Components and Line Sets click here.

Standard Features

  • Suitable for use with R-410A and R-22 refrigerants
  • Rust-proof, high-temperature, thermoplastic drain pans feature a low water-retention design
  • Available with check flowrater expansion device for heat pump or cooling-only applications
  • Rifled tubing and corrugated aluminum fin coils
  • Foil-faced insulation

Cabinet Features

  • High-quality post-paint cabinet
  • Split-seam front for easy access

Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Upflow / Downflow
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
2.5 Tons
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-22 / R-410A
Number of Rows
3
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
3/4 Inches
Coil Width
17 1/2 inches
Coil Height
22 inches
Coil Depth
21 inches
Plenum Opening Width
16.5 inches
Shipping Weight
40 lbs