Mini-splits are the ideal solution for conditioning areas where adding ductwork is impractical or too expensive. This includes older homes, bedrooms, sunrooms, additions, office spaces, computer rooms, sports arena skyboxes, and interior warehouse offices, to name just a few.

Standard Features

  • Soft Mode
  • Dry Mode
  • Sleep Mode
  • Child Lock
  • Auto Restart
  • Easy Clean Design
  • 24-Hour ON/OFF Timer
  • Intelligent Air / 3 Fan Speeds
  • Temperature Display
  • Remote Control
  • 1 Year Limited Warranty on Parts
  • 5 Years Limited Warranty on Compressor

Complete your system by selecting a line set from the Accessories tab above.  Line sets come in 15, 35, and 50 foot lengths.

Total Cooling Capacity BTU

The total amount of cooling delivered by the system. This number is inclusive of all interior air handlers.

Total Cooling Capacity BTU
22,000 BTU
Total Cooling Capacity
1.8 Ton(s)
Heating Capacity

The amount of heat, rated in BTUs that the item can produce.

Heating Capacity
955 BTU
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
21,000 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
13 SEER
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
7.7 HSPF
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Moisture Removal

The amount of water that can be removed from the air rated in pints per hour.

Moisture Removal
5.2 Pts/Hr
Maximum Fuse/Breaker

The maximum capacity breaker that the unit can be connected to (This is the best option for consistent performance)

Maximum Fuse/Breaker
25 Amps
Maximum Line Length

The maximum length of line set approved for use with this product.

Maximum Line Length
50 Feet
Maximum Height Difference

The maximum vertical distance between the condensing unit and the air handler.

Maximum Height Difference
16.4 Feet
Line Set Connection Type

There are two main types of connections for HVAC products brazed and flared. Brazed connections are typically used in standard split systems, and flare connections are typically used on mini splits and can be connected using a wrench.

Line Set Connection Type
Flare
Zones

The number of interior air handlers connected to the condensing unit. Typically one, two, or three zones.

Zones
1
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
5/8 Inches
Indoor Section Size, W x H x D
45 15/32 x 12 1/8 x 8 13/16 Inches
Sound Rating, Indoor

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Sound Rating, Indoor
46 / 48 / 50 Decibels
Sound Rating, Outdoor

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Sound Rating, Outdoor
61 Decibels
Outdoor Section Size, W x H x D
37 5/16 x 32 11/16 x 13 3/8 Inches
Indoor Section Weight
37.4 Lbs
Outdoor Section Weight
142.4 Lbs
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
5 Years
Parts Warranty
1 Years

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.