(800)865-5931 Monday to Friday 7:00 AM - 7:00 PM Central
0
Free Shipping See Details
|
No Sales Tax See Details
The Alpine AHOVA-24H-M13H (Item No. 607233) has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Monday - Friday

8:30 AM - 5:00 PM Central

This Alpine AHOVA-24H-M13H 2 Ton, 13 SEER Heat Pump, For R-22 Refrigerant has some minor cosmetic damage incurred during shipping. For detailed photos please click 'See Additional Images' above. This Alpine AHOVA-24H-M13H 2 Ton, 13 SEER Heat Pump, For R-22 Refrigerant meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Alpine AHOVA-H 13 SEER Series heat pump is made by Midea and is the outdoor air conditioning element in a versatile climate-control system designed to create perfect comfort.  It is exceptionally well constructed and features built in high and low pressure safety shut-off switches, components normally found only in high-end equipment.  This multi-functional, high-efficiency system meets all of your needs while offering industry-leading quality and unmatched value.

This heat pump requires an indoor air handler or evaporator coil as part of a complete system. The coil or air handler you should use depends on two factors about the condenser: the tonnage, and the efficiency rating ("SEER"). Usually, high efficiency condensers require a larger tonnage coil than the tonnage of the condenser. For example, a 2 ton 16 SEER condenser might be paired with a 3 ton evaporator coil. To find the specific coils and air handlers that are recommended by the manufacturer for this condenser, check the Accessories tab above. Also, you can view the manufacturer's specifications sheets at the Documents tab above.

Some models of condensers include an orifice (also called "flow rater" or "piston") in a small bag taped to the side of the condenser. If the condenser you purchase includes this orifice, you will need to replace the orifice already inside the evaporator coil or air handler you purchase with this orifice included with the condenser. Doing so makes the condenser and evaporator coil compatible. You can view this step-by-step guide to see how to easily change the orifice.

If you are installing a heat pump with a backup heat source which will be a fuel furnace, you will need to install a thermostat like the Honeywell VisionPro 8000 (TH8320U 1008) thermostat.  This thermostat switches between the two heat sources as needed and prevents both the heat pump and backup heat from running at the same time. 

Need help putting a complete system together?Use our easy System Selector and we’ll do it for you!

Please note that this equipment uses liquid refrigerant and that by federal law you must be EPA certified to handle the refrigerant. You can purchase this equipment without being certified, and if you are mechanically inclined you can perform about 90% of the equipment installation yourself. However, you must have a professional heating/cooling contractor do the final part of the installation which requires managing the refrigerant.

For Tips for Selecting Matched Components and Line Sets click here.

 Features:

  • High / low pressure switch
  • Temperature sensor
  • Factory-installed discharge muffler - helps insure quiet and stable operation
  • Low-pressure service valve - provides easy access for service and installation
  • Factory-installed accumulator - protects the compressor against liquid slugging
  • Crankcase heater - protects compressor from low ambient temperatures or refrigerant migration
  • High condenser coil temperature protection (127° F)
  • High-quality condenser coils with inner-groove copper pipe and high-efficiency aluminum fin absorbs condensation water for maximum heat exchange
  • Anti-rust - painted galvanized steel cabinet, 1000 hours salt spray test
  • Operating ambient temperature range: 14-109° F

 

Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
24,000 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
2 Tons
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
24,000 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
13 SEER
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-22
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
20 Amps
Compressor Type

Reciprocating compressors use a piston to compress the refrigerant.

Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

Compressor Type
Rotary
Low Pressure Safety Switch

A safety switch, that when/if the pressure in the system gets too low, it will turn off the equipment to avoid damaging it.

Low Pressure Safety Switch
Yes
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
3/4 Inches
Noise Level

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Noise Level
59 Decibels
Pad Size
24x24 Inches
Width
23 5/8 Inches
Depth
23 5/8 Inches
Height
24 15/16 Inches
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
5 Years
Parts Warranty
5 Years

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.