4 Ton, 14 to 16 SEER Condenser, R-410A Refrigerant Southwestern Sales Only

4 Ton, 14 to 16 SEER Condenser, R-410A Refrigerant Southwestern Sales Only

Model: Goodman GSX160481

Actual product may vary from photos.
highlights

Recommended for sales only within the Southwest region: CA, NV, AZ, NM.

For sales in all other states we suggest the Goodman GSX16S481 model

If you need assistance in selecting your equipment, please call us at (800) 865-5931.

 

The Goodman® GSX16 14 to 16 SEER Central Air Conditioner uses the environmentally friendly refrigerant R-410A and features energy efficiencies and operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. The GSX16 features a high-efficiency Copeland® scroll compressor and is designed for the consumer who desires superior comfort, quiet operation, and environmentally friendly air conditioning performance.

This central air conditioning condenser requires an indoor air handler or evaporator coil as part of a complete system. What tonnage coil or air handler should you use? It depends on two factors about the outside portion of the central air conditioning system: 1) the tonnage, and 2) the efficiency rating (listed as "SEER"). Usually, high efficiency central air conditioning condensers are required to use a larger tonnage evaporator coil than the tonnage of the outside central air condenser. (For example, a 2 ton central air conditioning condenser might be paired with a 3 ton or 3.5 ton evaporator coil.) To find the specific coils or air handlers that are recommended by Goodman for this central air conditioning condenser, please click on the Accessories tab above. (Also, you can view Goodman's specifications sheets at the Documents tab above).

In order to achieve the 16 SEER efficiency this central air conditioner must be installed with the manufacturer recommended evaporator coil, furnace, variable speed air handler, or variable speed modular blower and thermostatic expansion valve (TXV). (See the Accessories tab above for most compatible products, or Goodman's spec sheet found under the Documents tab above to verify central air conditioning efficiency with particular equipment combinations.) A 16 SEER system will reduce your electric bill approximately 7% - 8% more than a 15 SEER system.

Need help putting a complete central air conditioning system together? Use our easy System Selector and we’ll do it for you!

Please note that this air conditioning equipment comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. Yes, you can purchase this equipment without being EPA certified. And, if you are mechanically inclined you may perform about 90% of the equipment installation yourself. However, we strongly recommend to have a professional heating/cooling contractor do the final part of the installation including managing the refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this central air conditioner validates your warranty with Alpine.

Standard Features of this Central Air Conditioner

  • R-410A environmentally friendly refrigerant
  • High-efficiency Copeland® Ultratech scroll compressor
  • Factory-installed filter dryer
  • Fully charged for 15 feet of tubing length
  • Copper tube/enhanced aluminum fin coil
  • Sweat connection service valves with easy access to gauge ports
  • Contactor with lug connection
  • Ground lug connection
  • AHRI Certified
  • ETL Listed

Cabinet Features

  • Unique Goodman® brand louvered sound control top design
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When central air conditioner is properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

 

Also Consider
Specs
System Information
view information
Stages
Single Stage
view information
TXV Required
No
view information
Refrigerant
R-410A
Features
view information
Low Pressure Safety Switch
No
view information
High Pressure Safety Switch
Yes
Efficiency
view information
Energy Efficiency Ratio
12.0 - 13.0 EER
view information
SEER
14.0 - 16.0 SEER
Performance
view information
Total Cooling Capacity
4 Ton(s)
view information
Base Cooling Capacity
45500 BTU
view information
Compressor Type
Scroll
view information
Cooling Tonnage
4 Tons
view information
Noise Level
75 Decibels
Electrical Information
view information
Frequency
60 Hz
view information
Voltage Phase
1
view information
Maximum Overcurrent Protection (Breaker)
40 Amps
view information
Voltage
208 / 230 Volts
Line Set Information
view information
Liquid Line Size (OD)
3/8 Inches
view information
Suction Line Size (OD)
7/8 Inches
Product Dimensions
view information
Width
35 1/2 Inches
view information
Depth
35 1/2 Inches
view information
Height
36 1/4 Inches
view information
Pad Size
36x36 Inches
Shipping Weight
311 lbs
Warranty
view information
Compressor Warranty
10 Years With Online Registration
view information
Parts Warranty
10 Years
Certifications
view information
Qualifies for Govt. Money
No
view information
Approved for US Region(s)
North
view information
ENERGY STAR® Certified
No
Reviews
Let's Talk
Get expert assistance from our team
Call our product specialists at: (800) 865-5931
Sun 10am-3pm, Mon-Fri 7am-7pm, Sat 10am-4pm CT
© Copyright 2002-2024, Alpine Home Air Products
Privacy Policy