The Goodman ARUF18B14 (Item No. 610790) has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Monday - Friday

8:30 AM - 5:00 PM Central

Minor dents and scratches. Unit is fully functional. This Goodman ARUF18B14 1.5 Ton Standard Multi-Positional Air Handler has some cosmetic damage incurred during shipping. For detailed photos please click 'See Additional Images' above. This Goodman ARUF18B14 1.5 Ton Standard Multi-Positional Air Handler meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman ARUF Multi-Position Air Handler is suitable for use with R-410A refrigerant and may be installed in a variety of locations.  This air handler features a SmartFrame™ sub-structure that adds lateral stability, mounting locations for internal components, and additional insulation retention.

 For Tips for Selecting Matched Components and Line Sets click here.

Standard Features

  • All-aluminum evaporator coil
  • Check flowrater expansion device for cooling-only and heat pump applications
  • Direct-drive, multi-speed motor
  • Transformer and blower time-delay on all units
  • Easy single-bulb UV light compatibility
  • Complies with the Factory-sealed Air Handling Credit with or without field-installed filter kits as listed in the 2001 Florida Building Code, Chapter 13, Section 610.2.A.2.1
  • AHRI Certified; ETL Listed

Cabinet Features

  • New rigid SmartFrame™ cabinet
  • 21 inch depth for easy attic access
  • Galvanized leather grain-embossed finish
  • Glue-less cabinet insulation retention
  • Screw-less sides & back prevents condensation
  • Multi-position capability: upflow, downflow, horizontal or vertical
  • Coil-mounting track for quick repositioning
  • Tool-less filter access accommodates standard-size filters
  • Power supply entry at top; low-voltage entry at top and on left side
  • Easily convertible 4-way design
  • Multiple electrical knockouts
  • Heavy-gauge bottom plate

If your air handler will be installed above a conditioned space, your local code may require a secondary drain pan. See Accessories for details.

Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Downflow / Horizontal / Upflow
Blower Cooling Capacity

The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

Blower Cooling Capacity
1.5 Tons
Electric Heat Capabilities (Optional)

One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

Electric Heat Capabilities (Optional)
10 / 5 / 8 Kilowatts
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Blower Type

There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

Blower Type
Multi-Speed
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
15 Amps
Requires Downflow Kit

Kit is required when installed in a downflow application.

Requires Downflow Kit
Yes
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
3/4 Inches
Supply Air Opening Size

The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

Supply Air Opening Size
16.4 x 11.3 Inches
Return Air Opening Size

The dimensions of the opening where the air is recirculated back into the unit

Return Air Opening Size
14.2 x 19.5 inches
Shipping Weight
98 lbs
Width
17 1/2 Inches
Depth
21 Inches
Height
45 Inches
Voltage
208 / 230 / 240 Volts
Frequency
60 Hz
Voltage Phase
1