(800)865-5931 Monday to Friday 8:00 AM - 5:00 PM Central
0
Free Shipping See Details
|
No Sales Tax See Details

Amana ASZ140241

2 Ton, 14 or 15 SEER Heat Pump, R-410A Refrigerant

(0 Reviews)

Services

  • Liftgate Delivery $25
  • Shipping to Canada
    SHIPPING TO CANADA

    Canadian tax and shipping fees may be estimated prior to purchasing an item by completing the form below.

    TAXES
    Duties (%): N/A
    Canada Tax (%): N/A
    Brokerage: N/A
    Total taxes: N/A
    Quantity: Postal Code:
  • Flat Rate Returns $30
  • Pro Installation

The Amana ASZ14 14 SEER Heat Pump uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 14 SEER rating, the ASZ14 will help reduce energy consumption throughout the life of the system.

All Amana 14 / 15 SEER heat pumps must be installed with a bi-flow thermostatic expansion valve. This valve is installed in front of the indoor evaporator coil inline with the line set piping.

This heat pump can be 14 or 15 SEER, depending on which indoor unit it is paired with. If it is installed with the manufacturer recommended evaporator coil, an Amanavariable speed furnace, variable speed air handler, or variable speed modular blower, and also sometimes a thermostatic expansion valve (TXV), it is a 15 SEER system (see Accessories tab above for actual products compatible with this heat pump, or the "Instructions & Brochures" tab above for Amana's spec sheet details). A 15 SEER heat pump system will reduce your electric bill approximately 7% - 8% more than a 14 SEER heat pump system.

If you are installing a heat pump with a backup heat source which will be a fuel furnace, you will need to install an electronic all fuel kit.  This kit switches between the two heat sources as needed and prevents both the heat pump and backup heat from running at the same time. Alternatively, you can install the Honeywell VisionPro 8000 (TH8320U 1008) thermostat which has the all-fuel kit functionality built into it already, in which case an external all fuel kit would not be needed.

Need help putting a complete heat pump system together? Use our easy System Selector and we’ll do it for you!

Please note that this heat pump equipment comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. Yes, you can purchase this equipment without being EPA certified. And, if you are mechanically inclined you may perform about 90% of the equipment installation yourself. However, we strongly recommend to have a professional heating/cooling contractor do the final part of the installation including managing the refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this heat pump validates your warranty with Alpine.

Heat Pump's Standard Features

  • R-410A environmentally friendly refrigerant
  • High-efficiency Copeland® scroll compressor
  • High- and low-pressure switches
  • 850 RPM condenser fan motor
  • Liquid refrigerant return protection
  • Factory-installed, bi-flow liquid line filter dryer
  • Service valves with sweat connections and easy-access gauge ports
  • Copper tube/enhanced aluminum fin coil
  • Reliable time-initiated, temperature-terminated defrost control
  • Contactor with lug connection
  • Ground lug connection
  • ARI Certified
  • ETL Listed

Cabinet Features

  • Unique Amana sound control top design
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Top and side maintenance access
  • Service ports and controls are accessible while unit is operating
  • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
24,000 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
2 Tons
Heating Capacity

The amount of heat, rated in BTUs that the item can produce.

Heating Capacity
24,000 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
14 SEER
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
8.6 HSPF
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
25 Amps
Compressor Type

Reciprocating compressors use a piston to compress the refrigerant.

Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

Compressor Type
Scroll
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
3/4 Inches
TXV Required

A TXV is an inline metering device used to regulate the amount of refrigerant entering the evaporator coil. They are frequently used in high efficiency systems.

TXV Required
Yes
Pad Size
30x30 Inches
Shipping Weight
207 lbs
Voltage
208 / 230 Volts
Voltage Phase
1
Parts Warranty
10 Years