(800)865-5931 Monday to Friday 7:00 AM - 7:00 PM Central
0
Free Shipping See Details
|
No Sales Tax See Details
The Goodman GMS80603AX (Item No. 611875) has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Monday - Friday

8:30 AM - 5:00 PM Central

This Goodman 80% 60,000 BTU, GMS80603AX, Up/Horizontal Lonox Furnace has some cosmetic damage incurred during shipping. For detailed photos please click 'See Additional Images' above. This Goodman 80% 60,000 BTU, GMS80603AX, Up/Horizontal Lonox Furnace meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman GMS8/GDS8 multi-position gas furnaces feature a patented aluminized steel tubular heat exchanger and high-efficiency hot surface ignition system. These furnaces are run-tested for heating or combination heating/cooling applications. With a heavy-gauge, reinforced, wrap-around insulated steel cabinet and durable baked enamel finish, these gas heaters can be installed in a utility room, closet, alcove, basement or attic. (Not intended for use in mobile homes.)

Important Safety Notice

Furnace Features

  • Operates as a natural gas furnace out of the box, and can be easily converted to a propane furnace with optional propane conversion kit (see Accessories tab).
  • Corrosion-resistant, aluminized-steel tubular furnace heat exchanger
  • Furnace is designed for multi-position installation - Goodman GMS8: upflow, horizontal right or left; Goodman GDS8: dedicated downflow
  • Energy-saving, reliable hot surface ignition system with Goodman furnace patented adaptive learning algorithm to maximize igniter life
  • Aluminized steel inshot gas furnace burners
  • Energy-saving PSC, multi-speed, direct drive blower motor
  • Quiet, corrosion-resistant induced draft furnace blower assembly
  • Integrated Goodman furnace control with diagnostics
  • Low voltage terminal blocks
  • Multiple flame roll-out switches, blower door safety switch, outlet air-limit switch and pressure switch for proof of combustion air
  • 40VA transformer for heating and air conditioning control service
  • Combination redundant gas valve and regulator
  • A rotating combustion air blower (Goodman GMS8) that provides the option of venting the furnace through the top, right-hand side or left-hand side
  • Completely assembled, factory run-tested furnace for heating or combination heating/cooling application
  • Furnace has heavy-gauge, reinforced, fully insulated steel cabinet with durable baked-enamel finish
  • Attractive architectural gray paint finish
  • Heater's foil-face insulation lines the heat exchanger compartment
  • Coil and furnace fit flush for easy installation
  • Convenient left or right connection for gas and electric service
  • Bottom or side air inlet (Goodman GMS8)
  • Removable, solid-bottom block off
  • Complies with California NOx Standards

Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Horizontal / Upflow
Blower Cooling Capacity

The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

Blower Cooling Capacity
1.5 / 2 / 2.5 / 3 Tons
Maximum Input BTU

The maximum amount of heat that the unit can produce. The amount delivered into the space will be the input minus the efficiency loss also know as the output. For example a 100000 btu furnace at 80% efficiency will give you 80000 out btus of heat. The same size furnace at 95% will give you 95000 btus of heat.

Maximum Input BTU
60,000 BTU
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
48,000 BTU
Maximum CFM

The maximum amount of air that the blower can push. Rated in Cubic feet per minute or CFM.

Maximum CFM
1,157 @ 0.5
Efficiency (% AFUE)

The percentage of energy converted into output by the unit. The remaining percentage is lost during the conversion process. The higher the efficiency, the lower the operational cost.

Efficiency (% AFUE)
80 %
Blower Type

There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

Blower Type
Multi-Speed
Burner Stages

A single stage furnace has one heat setting. The furnace is either on at full capacity or it is off.

A two stage furnace has two different heat settings; one full capacity and a second lower heat setting. The advantage of a two stage furnace is that it extends the run time which does a better job distributing the air in your home. This helps improve your homes comfort level while reducing drafty areas.

A modulating furnace will heat on a low capacity until a call for high heat is sent to the furnace. Once a high heat call is initiated the furnace will slowly increase the burner level and blower speed over time, until reaching full capacity. The advantages are potentially reduced noise and better efficiency in some models. A modulating furnace should provide the best comfort level.

Burner Stages
Single
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
15 Amps
Fuel Type
Liquid Propane Convertible / Natural Gas
Vent Connection

The diameter of the vent connection on the furnace.

Vent Connection
4 Inches
Supply Air Opening Size

The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

Supply Air Opening Size
12.5 x 19.5 Inches
Product Weight
130 lbs
Meets CSA Standards

Canadian Standards Association

Meets CSA Standards
Yes
Meets Canadian OEE Standards

Standards established by Canada's Office of Energy Efficiency.

Meets Canadian OEE Standards
No
California Approved

LoNox feature meets State of California emissions requirements.

California Approved
Yes
Width
14 Inches
Depth
28 Inches
Height
33 3/8 Inches
Voltage
120 Volts
Frequency
60 Hz
Voltage Phase
1
Heat Exchanger Warranty
Lifetime
Parts Warranty
10 Years

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.