(800)865-5931 Monday to Friday 8:30 AM - 5:00 PM Central
0
Free Shipping See Details
|
No Sales Tax See Details
The Goodman CSCF3036N6 (Item No. 613562) has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Monday - Friday

8:30 AM - 5:00 PM Central

This Goodman CSCF3036N6 2.5 to 3 Ton, W 33 1/2 x H 25 x D 12, Horizontal Slab Evaporator Coil has some cosmetic damage incurred during shipping. Small dents on the cabinet. For detailed photos please click 'See Additional Images' above. This Goodman CSCF3036N6 2.5 to 3 Ton, W 33 1/2 x H 25 x D 12, Horizontal Slab Evaporator Coil meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman® CSCF Horizontal Slab Evaporator Coils are made for split system air conditioners and heat pumps. Each coil’s cabinet has a quality, galvanized-steel finish.

This coil can operate with a heat pump or condenser of two different tonnages, as noted in the product description above. The unit comes equipped with an orifice (flowrater) for the larger listed tonnage. If you wish to pair the coil with a condenser or heat pump of the smaller tonnage, an orifice in that tonnage will need to be used (unless a TXV is required instead). If you are purchasing a new Goodman heat pump or condenser, the required orifice can be found on our site by clicking the Accessories tab on the product page for that item. However, if you are purchasing this coil only and wish to pair it with equipment of the lower tonnage rating as listed on the description for this coil, you will need to separately purchase the smaller orifice and install it in the coil before operating. See this step-by-step guide to learn how to easily do so. Alternatively, instead of an orifice a thermostatic expansion valve (TXV) may be used or required for some equipment, such as 14 SEER and higher heat pumps and all equipment that uses R-410A refrigerant (see equipment spec sheets for details or call us for assistance).

For Tips for Selecting Matched Components and Line Sets click here.

Standard Features

  • Suitable for use with R-410A and R-22 refrigerants
  • Rust-resistant, high-temperature, thermoplastic drain pans with a secondary drain connection
  • Check flowrater expansion device
  • Copper tube/aluminum fin coil
  • Compact, versatile, right or left horizontal position
  • Copper sweat connections

Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Horizontal
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
3 Tons
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-22 / R-410A
Number of Rows
3
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
7/8 Inches
Orifice Size

The size of refrigerant metering device that ships with the coil.

Orifice Size
0.074 inches
Coil Width
33 1/2 inches
Coil Height
25 inches
Coil Depth
12 inches
Plenum Opening Width
24 inches
Plenum Opening Height
21 inches
Shipping Weight
44 lbs

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.