(800)865-5931 Monday to Friday 8:30 AM - 5:00 PM Central
0
Free Shipping See Details
|
No Sales Tax See Details

Goodman GSC140421 Central Air Conditioner (Item No. 4980)

3.5 Ton, 14 or 15 SEER Condenser, R22 Refrigerant

(0 Reviews)

Services

  • Flat Rate Returns $30
  • Pro Installation
  • Liftgate Delivery $25
  • Shipping to Canada
    SHIPPING TO CANADA

    Canadian tax and shipping fees may be estimated prior to purchasing an item by completing the form below.

    TAXES
    Duties (%): N/A
    Canada Tax (%): N/A
    Brokerage: N/A
    Total taxes: N/A
    Quantity: Postal Code: Calculate Shipping

This Goodman GSC140421 Central Air Conditioner 3.5 Ton, 14 or 15 SEER Condenser, R22 Refrigerant has some cosmetic damage incurred during shipping. For detailed photos please click 'See Additional Images' above. This Goodman GSC140421 Central Air Conditioner 3.5 Ton, 14 or 15 SEER Condenser, R22 Refrigerant meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman® GSC14 Air Conditioner features a high-efficiency Copeland® scroll compressor for improved temperature and humidity control and the unique Goodman® sound control top design for quiet operation. In addition, the unit has an attractive louvered metal guard that protects the coil from damage plus a powder-paint finish that provides premium durability and improved UV protection.

This unit can be 14 or 15 SEER, depending on which indoor unit it is paired with. If it is installed with the manufacturer recommended evaporator coil, a Goodman variable speed furnace, variable speed air handler, or variable speed modular blower, and also sometimes a thermostatic expansion valve (TXV), it is a 15 SEER system (see mfg. spec sheet under Documents tab above for specifics). A 15 SEER system will reduce your electric bill approximately 7% - 8% more than a 14 SEER system.

This condenser requires an indoor air handler or evaporator coil as part of a complete system. What tonnage coil or air handler should you use? It depends on two factors about the condenser: 1) the tonnage, and 2) the efficiency rating (listed as "SEER"). Usually, high efficiency condensers are required to use a larger tonnage coil than the tonnage of the condenser. (For example, a 2 ton condenser might be paired with a 3 ton or 3.5 ton evaporator coil.) To find the specific coils or air handlers that are recommended by the manufacturer for this condenser, please click on the "Accessories" tab above. (Also, you can view the manufacturer's specifications sheets at the Documents tab above).

Some models of the Goodman condensers include an orifice (also called "flow rater" or "piston") in a small bag taped to the side of the condenser. If the condenser you purchase includes this orifice, you will need to replace the orifice already inside the Goodman evaporator coil or air handler you purchase with this orifice included with the condenser. Doing so makes the condenser and evaporator coil compatible. You can view this step-by-step guide to see how to easily change the orifice. Need help putting a complete system together? Use our easy System Selector and we’ll do it for you! Please note that this equipment comes pre-charged with liquid refrigerant and that by federal law you must be EPA certified to handle the refrigerant. Yes, you can purchase this equipment without being certified. And, if you are mechanically inclined you can perform about 90% of the equipment installation yourself. However, you must have a professional heating/cooling contractor do the final part of the installation which requires managing the refrigerant.

For Tips for Selecting Matched Components and Line Sets click here.

Standard Features

  • High-efficiency Copeland® scroll compressor with internal pressure relief valve
  • Factory-installed liquid line filter dryer
  • 850 RPM condenser fan motor
  • High-efficiency copper tube/aluminum fin coil
  • R-22 refrigerant charged for 15’ of refrigerant line
  • Brass liquid and suction line service valves
  • Contactor with lug connection
  • ARI Certified
  • ETL Certified

Cabinet Features

  • Unique Goodman® sound control top design
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds

Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
40,000 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
3.5 Tons
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
14 SEER
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-22
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
30 Amps
Compressor Type

Reciprocating compressors use a piston to compress the refrigerant.

Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

Compressor Type
Scroll
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
7/8 Inches
TXV Required

A TXV is an inline metering device used to regulate the amount of refrigerant entering the evaporator coil. They are frequently used in high efficiency systems.

TXV Required
No
Pad Size
36x36 Inches
Shipping Weight
242 lbs
Voltage
208 / 230 Volts
Voltage Phase
1
Compressor Warranty
10 Years
Parts Warranty
10 Years

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.