The Goodman AVPTC42D14 (Item No. 613726) has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Monday - Friday

8:30 AM - 5:00 PM Central

This Goodman AVPTC42D14 3.5 Ton Multi-Positional Variable Speed Air Handler has some cosmetic damage incurred during shipping. Dented on all sides but cosmetic only. For detailed photos please click 'See Additional Images' above. This Goodman AVPTC42D14 3.5 Ton Multi-Positional Variable Speed Air Handler meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman® Multi-Position, Variable-Speed Air Handler is suitable for use with refrigerant R-410A (models ending in 14) and is compatible with the ComfortNet™ Communicating System family of products.

The AVPTC 's blower design includes a variable-speed direct current motor, which helps eliminate the cold blast of air upon heating start-up often associated with single-speed units. This air handler is ideal for either new or retrofit installations.

Standard Features

  • Compatible with the ComfortNet™ Communicating System family of products
  • Maximum four low-voltage wires required for operation in communicating mode
  • Auto configuration of the airflow and tonnage in communicating mode
  • In non-communicating mode, up to 12 field-selectable airflow settings can be adjusted to optimize the system’s CFM for each individual mode of operation
  • R-410A refrigerant-compatible
  • Factory-installed thermal expansion valves for cooling and heat pump applications
  • Variable-speed ECM blower motor
  • All-aluminum evaporator coil
  • Provides constant CFM over a wide range of static pressure conditions independent of duct system
  • Provides adjustable low CFM for efficient fan-only operation
  • CFM indicator with front-panel sight glass
  • Improved humidity control and comfort
  • Compatible with variable-capacity heat pumps and cooling applications
  • Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections
  • AHRI Certified; ETL Listed

Cabinet Features

  • Fully insulated, painted steel cabinet with attractive Architectural Gray finish
  • Compact, versatile upflow, downflow, or horizontal multi-position installations
  • Low-voltage cabinet connections; control circuit is arranged to permit staging
  • Power supply on top; low-voltage entry on top or side
  • Foil-faced insulation is glued in place and covers the entire blower case to reduce operating sound and cabinet condensation

Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Downflow / Horizontal / Upflow
Blower Cooling Capacity

The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

Blower Cooling Capacity
3.5 Tons
CFM (Low/High)
(800/1700) CFM
Electric Heat Capabilities (Optional)

One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

Electric Heat Capabilities (Optional)
10 / 15 / 20 / 5 / 6 / 8 Kilowatts
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Blower Type

There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

Blower Type
Variable Speed
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
15 Amps
Fuel Type
Electricity
Requires Downflow Kit

Kit is required when installed in a downflow application.

Requires Downflow Kit
Yes
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
7/8 Inches
Supply Air Opening Size

The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

Supply Air Opening Size
23.3125 x 11.3 Inches
Return Air Opening Size

The dimensions of the opening where the air is recirculated back into the unit

Return Air Opening Size
21.1875 x 19.5 inches
Shipping Weight
167 lbs
Width
24 1/2 Inches
Depth
21 Inches
Height
58 Inches
Voltage
208 / 230 / 240 Volts
Frequency
60 Hz
Voltage Phase
1
Parts Warranty
10 Years

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.