  • Configuration

    Configuration is the direction the conditioned air will pass through the unit.

    Upflow units will have the air come in from the bottom and blow out the top.

    Horizontal units will have the air go through the unit left to right, or right to left.

    Downflow units will have the air come in from the top of the unit, and blow out the bottom.

    Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

    Configuration
  • Blower Cooling Capacity

    The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

    Blower Cooling Capacity
  • Electric Heat Capabilities (Optional)

    One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

    Electric Heat Capabilities (Optional)
  • Refrigerant

    Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

    An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

    Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

    As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

    Refrigerant
  • Blower Type

    There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

    Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

    High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

    Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

    Blower Type
  • Voltage
  • Frequency
  • Voltage Phase
  • Maximum Overcurrent Protection (Breaker)

    The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

    Maximum Overcurrent Protection (Breaker)
  • Fuel Type
  • Requires Downflow Kit

    Kit is required when installed in a downflow application.

    Requires Downflow Kit
  • Liquid Line Connection Size

    The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

    Liquid Line Connection Size
  • Suction Line Connection Size

    The outside diameter of the suction line (the inside diameter of the connection on the equipment).

    Suction Line Connection Size
  • Orifice Size

    The size of refrigerant metering device that ships with the coil.

    Orifice Size
  • Depth
  • Height
  • Return Air Opening Size

    The dimensions of the opening where the air is recirculated back into the unit

    Return Air Opening Size
  • Supply Air Opening Size

    The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

    Supply Air Opening Size
  • Width
  • Shipping Weight
  • Limited Warranty
  • Parts Warranty
$723.99 Free Shipping
(0 Reviews)
  • Downflow / Horizontal / Upflow
  • 1.5 / 2 / 2.5 Tons
  • 10 / 5 / 7.5 Kilowatts
  • R-410A
  • Multi-Speed
  • 208 / 230 Volts
  • 60 Hz
  • 1
  • 15 Amps
  • Electricity
  • no
  • 3/8 Inches
  • 3/4 Inches
  • -
  • 20 5/8 Inches
  • 46 1/2 Inches
  • -
  • 10.3125 x 18 Inches
  • 19 5/8 Inches
  • 152 lbs
  • -
  • 5 Years
$407.99 Free Shipping
(1 Review)
  • Downflow / Horizontal / Upflow
  • 1.5 Tons
  • 10 / 5 / 7.5 Kilowatts
  • R-22 / R-410A
  • Multi-Speed
  • 208 / 230 Volts
  • 60 Hz
  • 1
  • 15 Amps
  • Electricity
  • Yes
  • 3/8 Inches
  • 3/4 Inches
  • 0.051 inches
  • 22 Inches
  • 46 3/4 Inches
  • 16 w x 20 1/4 d inches
  • 16.5 x 17 Inches
  • 18 1/2 Inches
  • 129 lbs
  • 10 Years
  • -