  • Configuration

    Configuration is the direction the conditioned air will pass through the unit.

    Upflow units will have the air come in from the bottom and blow out the top.

    Horizontal units will have the air go through the unit left to right, or right to left.

    Downflow units will have the air come in from the top of the unit, and blow out the bottom.

    Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

    Configuration
  • Blower Cooling Capacity

    The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

    Blower Cooling Capacity
  • Cooling Capacity

    Not sure what size you need? Feel free to use our easy sizing calculator.

    Cooling Capacity
  • Cooling Capacity

    Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

    Cooling Capacity
  • Maximum Heating Output BTU

    The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

    Maximum Heating Output BTU
  • Electric Heat Capabilities (Optional)

    One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

    Electric Heat Capabilities (Optional)
  • Heating Seasonal Performance Factor

    A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

    Heating Seasonal Performance Factor
  • SEER

    Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

    SEER
  • Refrigerant

    Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

    An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

    Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

    As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

    Refrigerant
  • Blower Type

    There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

    Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

    High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

    Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

    Blower Type
  • Voltage
  • Frequency
  • Voltage Phase
  • Maximum Overcurrent Protection (Breaker)

    The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

    Maximum Overcurrent Protection (Breaker)
  • Fuel Type
  • Compressor Type

    Reciprocating compressors use a piston to compress the refrigerant.

    Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

    Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

    Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

    Compressor Type
  • Low Pressure Safety Switch

    A safety switch, that when/if the pressure in the system gets too low, it will turn off the equipment to avoid damaging it.

    Low Pressure Safety Switch
  • Requires Downflow Kit

    Kit is required when installed in a downflow application.

    Requires Downflow Kit
  • Liquid Line Connection Size

    The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

    Liquid Line Connection Size
  • Suction Line Connection Size

    The outside diameter of the suction line (the inside diameter of the connection on the equipment).

    Suction Line Connection Size
  • TXV Required

    A TXV is an inline metering device used to regulate the amount of refrigerant entering the evaporator coil. They are frequently used in high efficiency systems.

    TXV Required
  • Orifice Size

    The size of refrigerant metering device that ships with the coil.

    Orifice Size
  • Depth
  • Height
  • Return Air Opening Size

    The dimensions of the opening where the air is recirculated back into the unit

    Return Air Opening Size
  • Supply Air Opening Size

    The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

    Supply Air Opening Size
  • Width
  • Noise Level

    The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

    Noise Level
  • Pad Size
  • Shipping Weight
  • Compressor Warranty
  • Limited Warranty
  • Parts Warranty
$685.99 Free Shipping
(0 Reviews)
  • Downflow / Horizontal / Upflow
  • 2.5 Tons
  • -
  • -
  • -
  • 10 / 15 / 5 / 7.5 Kilowatts
  • -
  • -
  • R-22 / R-410A
  • Multi-Speed
  • 208 / 230 Volts
  • 60 Hz
  • 1
  • 15 Amps
  • Electricity
  • -
  • -
  • Yes
  • 3/8 Inches
  • 7/8 Inches
  • -
  • 0.065 inches
  • 22 Inches
  • 51 Inches
  • 18 3/4 w x 20 1/4 d inches
  • 17 x 19.25 Inches
  • 21 1/4 Inches
  • -
  • -
  • 148 lbs
  • -
  • 10 Years
  • -
$944.99 Free Shipping
(0 Reviews)
  • -
  • -
  • 28,400 BTU
  • 2.5 Tons
  • 26,400 BTU
  • -
  • 8.2 HSPF
  • 13 SEER
  • R-410A
  • -
  • 208 / 230 Volts
  • 60 Hz
  • 1
  • 30 Amps
  • -
  • Scroll UltraTech™
  • Yes
  • -
  • 3/8 Inches
  • 3/4 Inches
  • No
  • -
  • 26 Inches
  • 32 1/4 Inches
  • -
  • -
  • 26 Inches
  • 72 Decibels
  • 30x30 Inches
  • 202 lbs
  • 10 Years With Online Registration
  • -
  • 10 Years