  • Configuration

    Configuration is the direction the conditioned air will pass through the unit.

    Upflow units will have the air come in from the bottom and blow out the top.

    Horizontal units will have the air go through the unit left to right, or right to left.

    Downflow units will have the air come in from the top of the unit, and blow out the bottom.

    Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

    Configuration
  • Blower Cooling Capacity

    The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

    Blower Cooling Capacity
  • Cooling Capacity

    Not sure what size you need? Feel free to use our easy sizing calculator.

    Cooling Capacity
  • Cooling Capacity

    Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

    Cooling Capacity
  • Maximum Input BTU

    The maximum amount of heat that the unit can produce. The amount delivered into the space will be the input minus the efficiency loss also know as the output. For example a 100000 btu furnace at 80% efficiency will give you 80000 out btus of heat. The same size furnace at 95% will give you 95000 btus of heat.

    Maximum Input BTU
  • Maximum Heating Output BTU

    The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

    Maximum Heating Output BTU
  • SEER

    Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

    SEER
  • Maximum CFM

    The maximum amount of air that the blower can push. Rated in Cubic feet per minute or CFM.

    Maximum CFM
  • Refrigerant

    Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

    An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

    Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

    As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

    Refrigerant
  • Efficiency (% AFUE)

    The percentage of energy converted into output by the unit. The remaining percentage is lost during the conversion process. The higher the efficiency, the lower the operational cost.

    Efficiency (% AFUE)
  • Blower Type

    There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

    Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

    High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

    Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

    Blower Type
  • Voltage
  • Frequency
  • Voltage Phase
  • Maximum Overcurrent Protection (Breaker)

    The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

    Maximum Overcurrent Protection (Breaker)
  • Fuel Type
  • Compressor Type

    Reciprocating compressors use a piston to compress the refrigerant.

    Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

    Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

    Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

    Compressor Type
  • ENERGY STAR® Qualified

    Products earn the ENERGY STAR label by meeting the energy efficiency requirements set forth in ENERGY STAR specifications. The EPA establishes these specifications based on the following set of principles:

    • Product categories must contribute significant energy savings nationwide.
    • Qualified products must deliver the features and performance demanded by consumers, in addition to increased energy efficiency.
    • If the qualified product costs more than a conventional, less-efficient counterpart, purchasers will recover their investment in increased energy efficiency through utility bill savings, within a reasonable period of time.
    • Energy efficiency can be achieved through broadly available, non-proprietary technologies offered by multiple manufacturers.
    • Product energy consumption and performance can be measured and verified with testing.
    • Labeling would effectively differentiate products and be visible for purchasers.

    ENERGY STAR® Qualified
  • Low Pressure Safety Switch

    A safety switch, that when/if the pressure in the system gets too low, it will turn off the equipment to avoid damaging it.

    Low Pressure Safety Switch
  • Liquid Line Connection Size

    The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

    Liquid Line Connection Size
  • Suction Line Connection Size

    The outside diameter of the suction line (the inside diameter of the connection on the equipment).

    Suction Line Connection Size
  • TXV Required

    A TXV is an inline metering device used to regulate the amount of refrigerant entering the evaporator coil. They are frequently used in high efficiency systems.

    TXV Required
  • Depth
  • Height
  • Supply Air Opening Size

    The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

    Supply Air Opening Size
  • Vent Connection

    The diameter of the vent connection on the furnace.

    Vent Connection
  • Width
  • Noise Level

    The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

    Noise Level
  • Pad Size
  • Product Weight
  • Shipping Weight
  • Compressor Warranty
  • Heat Exchanger Warranty
  • Parts Warranty
  • Meets CSA Standards

    Canadian Standards Association

    Meets CSA Standards
  • Meets Canadian OEE Standards

    Standards established by Canada's Office of Energy Efficiency.

    Meets Canadian OEE Standards
  • California Approved

    LoNox feature meets State of California emissions requirements.

    California Approved
$949.99 Free Shipping
(0 Reviews)
  • -
  • -
  • 28,800 BTU
  • 2.5 Tons
  • -
  • -
  • 14 SEER
  • -
  • R-410A
  • -
  • -
  • 208 / 230 Volts
  • 60 Hz
  • 1
  • 30 Amps
  • -
  • Scroll UltraTech™
  • -
  • Yes
  • 3/8 Inches
  • 3/4 Inches
  • Yes
  • 29 Inches
  • 32 1/2 Inches
  • -
  • -
  • 29 Inches
  • 72 Decibels
  • 30x30 Inches
  • -
  • 195 lbs
  • Lifetime With Online Registration
  • -
  • 10 Years
  • -
  • -
  • -
$799.99 Free Shipping
(0 Reviews)
  • Upflow
  • 3 / 3.5 / 4 / 5 Tons
  • -
  • -
  • 92,000 BTU
  • 86,000 BTU
  • -
  • 2,000 @ 0.5
  • -
  • 92.1 %
  • Multi-Speed
  • 120 Volts
  • 60 Hz
  • 1
  • 15 Amps
  • Liquid Propane Convertible / Natural Gas
  • -
  • No
  • -
  • -
  • -
  • -
  • 28 3/4 Inches
  • 40 Inches
  • 23 x 19.875 Inches
  • 2 Inches
  • 24 1/2 Inches
  • -
  • -
  • 170 lbs
  • -
  • -
  • Lifetime
  • 10 Years
  • Yes
  • Yes
  • Yes

In 2002 Alpine Home Air Products became the first company to sell heating, air conditioning and indoor air-quality products online. We have proudly served hundreds of thousands of customers, helping them save time and money by buying their products direct.