(800)865-5931 Open Fri 7:30am-5pm, Sat 9am-2pm CT
AMERICA'S HEATING & COOLING STORE™
EST. 2002
Home Air Products™
0
My Location: Ashburn, VA [Change]
|
Free Shipping See Details
|
No Sales Tax See Details
Enter your zip for personalized product and service recommendations.
YOUR SHOPPING EXPERIENCE IS NOW PERSONALIZED.
Actual product may vary from photos.

Panasonic PMZ36DR19-9W-9W-9W-9W-12W

36,000 BTU (3.0 Ton) 18.5 SEER Ductless Mini-Split 5-Zone Heat Pump

Have It Installed

Professional installation now available in Ashburn, VA!

  • Free online quotes
  • No home visit
Learn More
In Stock and Ready to Ship. (If ordered by 1 p.m. CST M-F, ships same day. All items on your order must be in stock for same-day shipping.)

Want to know more about ductless mini-split systems? View our video:

"Ductless Mini-Split Air Conditioning (and Heating) Systems"

 

Panasonic’s Ductless Mini-Split Air Conditioner & Heat Pump products offer wide versatility in solving your cooling and heating requirements for a single or multiple rooms. The Indoor unit(evaporator) is mounted inside the room, enclosed in a handsome space saving cabinet. It is connected to the outdoor unit (condenser) via refrigerant lines & inter-unit wiring through a 3-1/2” opening in the wall. Since no ductwork is required, installation is simple, fast & efficient. The indoor unit has been uniquely designed to provide Whisper Quiet operation while delivering comfort throughout the room(s). Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted systems, with whisper quiet operations, quality & reliability you can count on.

 

Flexible Indoor Unit Combinations

Systems with indoor units ranging from 6900 BTU to 24000 BTU are available, ready to provide optimal efficient cooling and heating for rooms of various sizes. When cooling or heating multiple rooms or spaces, their combined capacity reaches 46,000 BTU!  Alpine Home Air products offers 145 unique Panasonic multi zone combinations!  You can see our selection HERE!

Inverter Technology

Panasonic's inverter provides optimum power control and extremely efficient operation by changing the power supply frequency. The result is speedy, flexible operation using less electricity.

 

Features

  Microprocessor-Controlled Operation

Microprocessor control ensures that the temperature and humidity levels in the room are always comfortable.

 

Wireless Remote Control

Panasonic’s infrared Remote Control with and easy to read LCD Display, gives the user the capability to adjust & set temperature, sweep (louver control), fan speeds, timer and more, for complete automatic operation.

 

 

Dry Mode

By coupling compressor and fan operation, intermittent operation can be precisely controlled according to room temperature, so that air is efficiently dehumidified.

 

 

3 Fan Speeds and Automatic Fan Operation

Convenient microprocessor control automatically adjusts fan speed to High, Medium or Low. According to room temperature to maintain a comfortable airflow throughout the room.

 

 

Air Sweep Control

The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.

 

 

Louver Control

Louver can be manually set to the desired angle by remote control.

 

 

 

Automatic Heating and Cooling Changeover

After setting the temperature and functions you desire, just relax. If the room temperature is higher than the set temperature, cooling operation begins. If the room temperature is lower than the set temperature, heating operation begins. During normal thermostat cycle operation, cooling and heating operations automatically change in accordance with set temperature, time and room temperature. (Single Zone Heat Pump unit only)

 

 

 

1-hour OFF Timer

When this button is pushed either while the unit is operating or while it is stopped, the unit will operate for one hour and then switch off automatically.

 

 

24-hour Clock with ON/OFF Program Timer

The remote control unit allows you to set a wide variety of timer-based operations. Such functions include automatic ON/OFF with a timer setting, same time ON/OFF every day, ON timer, OFF timer and Combination timer.

 

 

 

Night Setback Mode for Cooling and Heating

Cooling and DRY Mode: With the Night Setback Mode, the air conditioner automatically raises the setting temperature 2°F after 30 minutes, and then another 2°F after the next 30 minutes. Heating Mode: With the Night Setback Mode, the setting temperature is automatically lowered 4°F after 30 minutes, and then another 4°F after the next 30 minutes. This saves energy without sacrificing comfort and is ideal for gentle cooling and heating.

 

 

 

Automatic Restart Function after Power Failure

This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.

 

 

 

Hot Start Heating System

Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cold blasts at the beginning while the heat pump is warming up. (Heat pump unit only)

 

 

 

 

 

Electric Refrigerant Control Valve

The circulation volume of the refrigerant is controlled by a pulse type electric control valve. In order to attain optimum efficiency, when the power is switched ON, the opening degree of the electric control valve is controlled between 90 and 480 steps.

 

 

Quiet Mode

LOW, low fan speed for extra quiet operation.

 

 

 

Filter Sign

Filter sign informs you when filter maintenance is necessary.

 

 

 

Self-Diagnosing Function

Details of previous warnings are stored and can be verified on the liquid crystal display. This makes it easier to diagnose malfunctions, greatly reducing service labor. (Wired remote controller)

 

 

 

Anti-microbial Filter

Anti-microbial Filter by 3M. This filter inhibits the growth of mold and mildew, and helps to create clean air.
 

 

LINE SETS COME IN FOUR(4) DIFFERENT LENGTHS AND ARE NEEDED TO COMPLETE ANY MINISPLIT INSTALLATION.

Visit our Accessories page where you will find the appropriate line set required to complete your minisplit installation and to learn how to get the most out of your new Panasonic Multi Zone System.

 

 

Included in the Panasonic PMZ36DR19-9W-9W-9W-9W-12W Box:

(1) CU-5E36QBU Outdoor Condenser
(4) CS-E9RKUAW 9,000 BTU Indoor Wall Mount Air Handler
(1) CS-E12RKUAW 12,000 BTU Indoor Wall Mount Air Handler
(5) Wireless Remote

Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
46000 BTU
Heating Capacity

The amount of heat, rated in BTUs that the item can produce.

Heating Capacity
64500 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
18.5 SEER
Energy Efficiency Ratio

The measure of air conditioner efficiency at its maximum load

Energy Efficiency Ratio
9.6 EER
Coefficient of Performance

Coefficient of Performance is the efficiency ratio of the amount of heating or cooling provided by a heating or cooling unit to the energy consumed by the system. The higher the Coefficient of Performance the more efficient the system. Resistance electrical heating (such as electric baseboards) for example has a Coefficient of Performance of 1.0

Coefficient of Performance
3.82 COP
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
10 HSPF
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Minimum Ampacity
30 Amps
Maximum Fuse/Breaker

The maximum capacity breaker that the unit can be connected to (This is the best option for consistent performance)

Maximum Fuse/Breaker
45 Amps
Line Set Connection Type

There are two main types of connections for HVAC products brazed and flared. Brazed connections are typically used in standard split systems, and flare connections are typically used on mini splits and can be connected using a wrench.

Line Set Connection Type
Flare
Compressor Type

Reciprocating compressors use a piston to compress the refrigerant.

Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

Scroll Ultratech™ compressors are advanced scroll compressors which offer more features and better diagnostics.

Compressor Type
Inverter
Operating Temperature
- 5 °F
Zones

The number of interior air handlers connected to the condensing unit. Typically one, two, or three zones.

Zones
5
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
(5)1/4 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
(5) 3/8 Inches
Total Weight
283 Lbs
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
7 Years
Parts Warranty
5 Year
*Any accessories purchased with the Panasonic PMZ36DR19-9W-9W-9W-9W-12W, are eligible for free shipping.
REQUIRED COMPONENTS FOR INSTALLATION
Alpine Mini Split Wire
Alpine MW4/025

25' 14/4 Stranded Ductless Mini-Split Wire - Non-Shielded (600 Volt)

$29.99 Qty:
Alpine Mini Split Wire
Alpine MW4/050

50' 14/4 Stranded Ductless Mini-Split Wire - Non-Shielded (600 Volt)

$49.99 Qty:
Diversitech Mini-Split Condenser Pad
DiversiTech EL1838-3

E-Lite 18" x 38" x 3" Mini-Split Condenser Pad

$33.99 Qty:
Coiled 20ft Drain Hose
Rectorseal 83003

5/8in Inner Diameter Drain Hose, 20ft Length

$27.99 Qty:
 Yellow Jacket 19173
Yellow Jacket 19173

19173 Adapter 5/16" x 1/4" for Ductless Mini-Split Systems

$17.99 Qty:
DiversiTech EDS-60U
Alpine AG-DCT

Safety Non-Fused Electrical Disconnect

$12.99 Qty:
Hitachi LS143814-15 Line Set
Alpine 40680150B3B6

15 Foot 3/8 SL 1/4 LL Ductless Mini-Split Line Set

$79.99 Qty:
Hitachi LS143814-15 Line Set
Alpine 40680250B3B6

25 Foot 3/8 SL 1/4 LL Ductless Mini-Split Line Set

$107.99 Qty:
Hitachi LS143814-15 Line Set
Alpine 40680350B3B6

35 Foot 3/8 SL 1/4 LL Ductless Mini-Split Line Set

$126.99 Qty:
Hitachi LS143814-15 Line Set
Alpine 40680500B3B6

50 Foot 3/8 SL 1/4 LL Ductless Mini-Split Line Set

$167.99 Qty:
AC INSTALLATION SUPPLIES
Alpine Mini Split Wire
Alpine MW4/125

125' 14/4 Stranded Mini-Split Wire - Non-Shielded (600 Volt)

$114.99 Qty:
Alpine Mini Split Wire
Alpine MW4/250

250' 14/4 Stranded Mini-Split Wire - Non-Shielded (600 Volt)

$230.99 Qty:
ACCESSORIES FOR MINI-SPLIT SYSTEMS
Diversitech 230-B
DiversiTech 230-B2M

Wall Bracket for Ductless Mini-Split Condensers, 165 lbs Weight Capacity

$49.99 Qty:
Diversitech 230-MB
DiversiTech 230-MB14W

(2-Pack)14" Mounting Blocks for Ductless Mini-Split Air Conditioner and Heat Pump Condensers

$13.99 Qty:
Diversitech 230-MBCW
DiversiTech 230-MBCW

(4-Pack) End Caps for DiversiTech 230-MB Mounting Blocks

$6.99 Qty:
Diveritech ACB-30
Diversitech ACB-30

Outdoor Wall Bracket for Ductless Mini-Split Condensers, 600 lbs Weight Capacity

$59.99 Qty:
Panasonic Expander-Reducer
Panasonic CZ-MA2P

Tube Size Expander 1/2" to 3/8"

$12.99 Qty:
Large drain hose coiled
Rectorseal 83002

5/8in Coil Standard Drain Hose 164ft Length

$67.99 Qty:
Large drain hose coiled
Rectorseal 83004

5/8in Coil UV Resistant Drain Hose 164ft Length

$80.99 Qty:
aspmauni
Rectorseal 83809

Aspen Mini Aqua 100-230V Condensate Pump

$146.99 Qty:
ASPMWUNI
Rectorseal 83939

Aspen Mini White 100-250V Condensate Pump

$146.99 Qty:
Product Image
Rectorseal 97705

Rectorseal 97705 Mighty Bracket

$99.99 Qty:
AIR BOOSTERS
as1
Tjernlund AS1

75 CFM Room-to-Room Ventilator, 120 VAC Hardwired

$134.99 Qty:
AIR CONDITIONING SYSTEM PROTECTORS
Diversitech CGB-AER Main
Diversitech CGB-AER

Coil Guard - Aerosol, Blue

$21.99 Qty:
CONDENSATION CONTROL
SS610E no box
Rectorseal SS610E

Safe-T-Switch Electronic Condensate Overflow Switch

$69.99 Qty:
ELECTRICAL WHIPS
Electrical Whip 4
Alpine AG-WHP8

3/4 x 48 Inches, #8 Gauge Electrical Whip

$15.99 Qty:
MINI-SPLIT SYSTEM LINE SETS
 Hitachi LS143814-15 Line Set
Alpine 40680650B3B6

65 Foot 3/8 SL 1/4 LL Ductless Mini-Split Line Set

$217.99 Qty:
OUTDOOR LINE SET COVERS
Diversitech 230-WS2
DiversiTech 230-WS2

2.5" Wall Sleeve for SpeediChannel™ Line Set Covers

$9.99 Qty:
TOOLS
Diversitech 358-20
Diversitech 358-20

Foam-Plus™ Foaming Coil Cleaner – 19 oz. Aerosol

$9.99 Qty:
HDT303K
Diversitech HDT303K

Deluxe Digital Thermometer

$24.99 Qty:
Get expert assistance from our team
Call our product specialists at 800-865-5931
Open Fri 7:30am-5pm, Sat 9am-2pm CT
Bill
Dan
Jack
Joseph
Peter
Russ
Message
Please enter a message
Email
Please use a valid email
Phone (optional)
Please use a valid phone number
Name (optional)
Please use a valid phone number