(800)865-5931 Mon-Tue 7am-7pm, Wed-Fri 8am-6pm, Sat 9am-2pm CT
AMERICA'S HEATING & COOLING STORE™
EST. 2002
Home Air Products™
118
My Location: Ashburn, VA [Change]
|
Free Shipping See Details
|
No Sales Tax See Details
Enter your zip for personalized product and service recommendations.
YOUR SHOPPING EXPERIENCE IS NOW PERSONALIZED.
The Goodman AVPTC60D14-GSX140601 SND-KIT 4 has been discontinued.
TRY THIS INSTEAD
Please call us for a suitable alternate product.

(800) 865-5931

Mon-Tue 7am-7pm, Wed-Fri 8am-6pm, Sat 9am-2pm CT

Save money with this Goodman Scratch 'N Dent Kit! This AHRI-matched bundle includes a NEW Goodman 5 Ton 14 SEER GSX140601 Central Air Conditioner Condenser, along with a Scratch 'N Dent Goodman AVPTC60D14 5 Ton Multi-Positional Variable Speed Air Handler. Because one item has sustained cosmetic shipping / warehouse damage, we have greatly discounted this package, resulting in substantial SAVINGS for you!

 

About the Goodman GSX140601 Condenser:

This Goodman GSX140601 Condenser is a new, undamaged unit.

For more information on this product, click here.

The Goodman® GSX14 14 SEER Central Air Conditioner uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. The GSX14 central air conditioner features a high-efficiency Copeland® scroll compressor and is designed for the consumer who desires superior comfort, quiet operation, and environmentally friendly cooling performance.

This central air unit can be 14 or 15 SEER depending on which indoor unit it is paired with. If it is installed with the manufacturer-recommended evaporator coil, variable speed furnace, variable speed air handler, or variable speed modular blower, and also sometimes a thermostatic expansion valve (TXV), it is a 15 SEER system (see Accessories tab above for actual products compatible with this central air conditioner, or the Documents tab above for Goodman's spec sheet details). A 15 SEER central air conditioning system will reduce your electric bill approximately 7% more than a 14 SEER system.

Some models of the Goodman condensers include an orifice (also called "flow rater" or "piston") in a small bag taped to the side of the condenser. If the condenser you purchase includes this orifice, you will need to replace the orifice already inside the evaporator coil or air handler you purchase with this orifice included with the condenser. Doing so makes the condenser and evaporator coil compatible. You can view this step-by-step guide to see how to easily change the orifice.

Need help putting a complete central air conditioning system together? Use our easy System Selector and we’ll do it for you!

Please note that this equipment comes precharged with R-410A liquid refrigerant, and by Federal law cannot be released to the atmosphere. You can purchase this equipment without being certified, and if you are mechanically inclined you can perform about 90% of the equipment installation yourself. However, you must have a professional heating/cooling contractor do the final part of the installation which requires managing the refrigerant.

For Tips for Selecting Matched Components and Line Sets click here.

 

* This Goodman GSX14 model meets or exceeds minimum requirements set in 2015 Regional Cooling Efficiency Standards 

 

Central Air Conditioner's Standard Features

  • Energy-efficient Copeland® scroll compressor
  • Factory-installed filter drier
  • Copper tube/aluminum fin coil
  • Service valves with sweat connections and easy-access gauge ports
  • Contactor with lug connection
  • Ground lug connection
  • AHRI Certified
  • ETL Listed

 

Cabinet Features

  • Goodman® brand louvered sound control top design
  • Steel louver coil guard
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds

 

About the Goodman AVPTC60D14 (Item No. 624243) Air Handler:

This Goodman AVPTC60D14 (Item No. 624243) Air Handler has some cosmetic damage incurred during shipping. Large dents around top. Left side dented at the top. Scratches and dings on all sides. For detailed photos please click 'See Additional Images' above. This Goodman AVPTC60D14 (Item No. 624243) Air Handler meets the full manufacturer's specifications, comes with the full manufacturer's warranty, and includes Alpine's premium guarantee.

For product specs and photographs of product in its original condition, click here.

The Goodman® Multi-Position, Variable-Speed Air Handler is suitable for use with refrigerant R-410A (models ending in 14) and is compatible with the ComfortNet™ Communicating System family of products.

The AVPTC 's blower design includes a variable-speed direct current motor, which helps eliminate the cold blast of air upon heating start-up often associated with single-speed units. This air handler is ideal for either new or retrofit installations.

Standard Features

  • Compatible with the ComfortNet™ Communicating System family of products
  • Maximum four low-voltage wires required for operation in communicating mode
  • Auto configuration of the airflow and tonnage in communicating mode
  • In non-communicating mode, up to 12 field-selectable airflow settings can be adjusted to optimize the system’s CFM for each individual mode of operation
  • R-410A refrigerant-compatible
  • Factory-installed thermal expansion valves for cooling and heat pump applications
  • Variable-speed ECM blower motor
  • All-aluminum evaporator coil
  • Provides constant CFM over a wide range of static pressure conditions independent of duct system
  • Provides adjustable low CFM for efficient fan-only operation
  • CFM indicator with front-panel sight glass
  • Improved humidity control and comfort
  • Compatible with variable-capacity heat pumps and cooling applications
  • Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections
  • AHRI Certified; ETL Listed

Cabinet Features

  • Fully insulated, painted steel cabinet with attractive Architectural Gray finish
  • Compact, versatile upflow, downflow, or horizontal multi-position installations
  • Low-voltage cabinet connections; control circuit is arranged to permit staging
  • Power supply on top; low-voltage entry on top or side
  • Foil-faced insulation is glued in place and covers the entire blower case to reduce operating sound and cabinet condensation

 

Configuration

Configuration is the direction the conditioned air will pass through the unit.

Upflow units will have the air come in from the bottom and blow out the top.

Horizontal units will have the air go through the unit left to right, or right to left.

Downflow units will have the air come in from the top of the unit, and blow out the bottom.

Unsure of what configuration your home needs? Call us at 800-865-5931. Monday through Friday, 8:30am to 5:00pm CST

Configuration
Downflow / Horizontal / Upflow
Blower Cooling Capacity

The tonnage of air conditioning that can be moved effectively by the blower. You want to make sure that the blower is appropriately sized for the air conditioner. If it is too small the coil could ice up. If it is too large than the air coming out of the ducts won't be cold enough.

Blower Cooling Capacity
5 Tons
Cooling Capacity

Not sure what size you need? Feel free to use our easy sizing calculator.

Cooling Capacity
60000 BTU
Cooling Capacity

Not sure what size you need? Feel free to watch an informational video and use our easy sizing calculator.

Cooling Capacity
5 Tons
Maximum Heating Output BTU

The amount of heat, rated in British Thermal Units (BTUs), that the unit can deliver into the space. Not sure how many BTUs you need? Try our easy Equipment Sizing Estimator.

Maximum Heating Output BTU
60000 BTU
SEER

Seasonal Energy Efficiency Ratio (SEER) is a measure of cooling over an entire season. It is determined by comparing the amount of cooling produced in BTUs in relation to the amount of electricity used. A higher SEER means a system is more energy efficient and would provide comfort at a lower utility cost than a lower SEER system.

SEER
14 SEER
CFM (Low/High)
(1600x2000) CFM
Electric Heat Capabilities (Optional)

One kilowatt equals 3,400 BTU's of heat (British Thermal Units).

Electric Heat Capabilities (Optional)
10 / 15 / 20 / 25 / 5 / 8 Kilowatts
Energy Efficiency Ratio

The measure of air conditioner efficiency at its maximum load

Energy Efficiency Ratio
11.7 EER
Heating Seasonal Performance Factor

A measure of heat pump efficiency while in a heating mode. The higher the number the better the energy efficiency.

Heating Seasonal Performance Factor
9.75 HSPF
Refrigerant

Inside air conditioning systems are liquid/gas refrigerant. There are two types of this refrigerant available for use, R-22 (more commonly known as Freon), and a newer alternative R-410A.

An air conditioning system does not consume refrigerant, but reuses it. As long as there are no leaks in the refrigerant circuit, there is no need to ever add more refrigerant to an air conditioning system.

Although R-22 is an effective refrigerant, if it is released into the atmosphere it can contribute to the depletion of the Earth’s ozone layer. The EPA has mandated the phasing out the use of R-22. It is being replaced by R-410A.

As of 2010, manufacturers are required to make all new air conditioners with R-410A. However, R-22 is still available for sale in existing pre-2010-manufactured equipment, and for use in servicing existing R-22 equipment. By 2020, R-22 will no longer be manufactured, but will still be recycled and available for sale.

Refrigerant
R-410A
Blower Type

There are three main type of blowers: Multi-Speed, High-Efficiency Multi-Speed, and Variable Speed.

Standard Multi-Speed blowers have different speed options and you select the speed that the blower will operate at depending on the function it is performing (ex. different speeds for fan, AC, and heating functions).

High-Efficiency Multi-Speed blowers are designed to maintain a constant torque and in doing so will maintain air-flow and use less electricity.

Variable Speed blowers will adjust their speed during operation. The result is a blower that will run at lower speeds for longer periods of time (this improves the air flow and increases electrical efficiency).

Blower Type
Variable Speed
Maximum Overcurrent Protection (Breaker)

The maximum capacity breaker in the building's circuit panel that can be used on the dedicated electrical line supplying the equipment.

Maximum Overcurrent Protection (Breaker)
15 / 50 Amps
Fuel Type
Electricity
Compressor Type

Reciprocating compressors use a piston to compress the refrigerant.

Rotary compressors utilize a roller rotating eccentrically inside a cylinder and a spring mounted blade always rubbing against the roller. As the eccentric rotates towards the blade, the space is decreased and the refrigerant is compressed. Rotary compressors are very efficient.

Scroll compressors consists of 2 scrolls to pressurize refrigerant. Often 1 scroll is fixed and the other orbits eccentrically compressing the gas between the scrolls. Scroll compressors are quiet, smooth and offer highest efficiency ratio of all compressor types.

Scroll Ultratechâ„¢ compressors are advanced scroll compressors which offer more features and better diagnostics.

Compressor Type
Scroll
Requires Downflow Kit

Kit is required when installed in a downflow application.

Requires Downflow Kit
Yes
Low Pressure Safety Switch

A safety switch, that when/if the pressure in the system gets too low, it will turn off the equipment to avoid damaging it.

Low Pressure Safety Switch
Yes
Liquid Line Connection Size

The outside diameter of the liquid line pipe (the inside diameter of the connection on the equipment).

Liquid Line Connection Size
3/8 Inches
Suction Line Connection Size

The outside diameter of the suction line (the inside diameter of the connection on the equipment).

Suction Line Connection Size
7/8 Inches
TXV Required

A TXV is an inline metering device used to regulate the amount of refrigerant entering the evaporator coil. They are frequently used in high efficiency systems.

TXV Required
Yes
Supply Air Opening Size

The dimensions of the opening that the air is discharged through. This is the section where you would attach the supply plenum.

Supply Air Opening Size
23.3125 x 11.3 Inches
Return Air Opening Size

The dimensions of the opening where the air is recirculated back into the unit

Return Air Opening Size
21.1875 x 19.5 inches
Noise Level

The noise produced by the unit rated in decibels. 30dbs is equivalent to a whisper, 60dbs is equivalent to a normal conversation, 90 dbs is equivalent to a lawn mower.

Noise Level
75 Decibels
Pad Size
36x36 Inches
Shipping Weight
481 lbs
Voltage
208 / 230 Volts
Frequency
60 Hz
Voltage Phase
1
Compressor Warranty
10 Years With Online Registration
Parts Warranty
10 Years
*Any accessories purchased with the Goodman AVPTC60D14-GSX140601 SND-KIT 4, are eligible for free shipping.
DOWNFLOW KITS
DPI
Goodman DFK-D

Downflow Kit for ARUF, ARPT, ASPT, ASUF & AVPTC Air Handlers (D Chasis)

$59.99 Qty:
THERMOSTATIC EXPANSION VALVES (TXV)
TX5N4
Goodman TX5N4

3.5 To 5 Ton TXV Kit - R-410A Refrigerant

$87.00 Qty:
Get expert assistance from our team
Call our product specialists at 800-865-5931
Mon-Fri 8am-5:30pm, Sat 9am-2pm CT
Brian
Dan
Jack
Joseph
Peter
Russ
Message
Please enter a message
Email
Please use a valid email
Phone (optional)
Please use a valid phone number
Name (optional)
Please use a valid phone number