4 Ton, 15.2 SEER2 Condenser, R-410A Refrigerant

Model: Goodman GSXH504810

Actual product may vary from photos.

Model: Goodman GSXH504810

Delivers reliable cooling to every corner of your home

Sturdy design for long term durability

Built for simple installation and easy maintenance

Peace of mind with 10 year warranty (with registration)

$2,806.00
Or as low as

Add to Cart for Discount

The Goodman GSXH504810 is no longer available for sale.
Express Pay Available
highlights

The Goodman® GSXH5 15.2 SEER2 Central Air Conditioner uses the environmentally friendly refrigerant R-410A and features energy efficiencies and operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. The GSXH5 features a high-efficiency scroll compressor and is designed for the consumer who desires superior comfort, quiet operation, and environmentally friendly air conditioning performance.

 

This central air conditioning condenser requires an indoor air handler or evaporator coil as part of a complete system. What tonnage coil or air handler should you use? It depends on two factors about the outside portion of the central air conditioning system: 1) the tonnage, and 2) the efficiency rating (listed as "SEER2"). Usually, high efficiency central air conditioning condensers are required to use a larger tonnage evaporator coil than the tonnage of the outside central air condenser. (For example, a 2 ton central air conditioning condenser might be paired with a 3 ton or 3.5 ton evaporator coil.) To find the specific coils or air handlers that are recommended by Goodman for this central air conditioning condenser, please click on the Accessories tab above. (Also, you can view Goodman's specifications sheets at the Documents tab above).

 

In order to achieve the 15.2 SEER2 efficiency this central air conditioner must be installed with the manufacturer recommended evaporator coil and thermostatic expansion valve (TXV), furnace plus evaporator coil and TXV valve, high efficiency air handler with an internal TXV valve, or variable speed modular blower plus evaporator coil and TXV valve. (See the Accessories tab above for most compatible products, or speak to a product specialist at 1-800-865-5931 to verify central air conditioning efficiency with particular equipment combinations).

 

Need help putting a complete central air conditioning system together? Use our easy System Selector and we’ll do it for you!

 

Please note that this air conditioning equipment comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. Yes, you can purchase this equipment without being EPA certified. And, if you are mechanically inclined you may perform about 90% of the equipment installation yourself. However, we strongly recommend to have a professional heating/cooling contractor do the final part of the installation including managing the refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this central air conditioner validates your warranty with Alpine.

 

Standard Features of this Central Air Conditioner

  • R-410A environmentally friendly refrigerant
  • High-efficiency scroll compressor
  • Factory-installed filter dryer
  • Fully charged for 15 feet of tubing length
  • Copper tube/enhanced aluminum fin coil
  • Sweat connection service valves with easy access to gauge ports
  • Contactor with lug connection
  • Ground lug connection
  • AHRI Certified
  • ETL Listed

 

Cabinet Features

  • Removable grille-style top design compliant with UL 60335-2-40
  • Heavy-gauge galvanized-steel cabinet
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Steel louver coil guard
  • Single-panel access to controls with space provided for field-installed accessories
  • When central air conditioner is properly anchored, meets the 2020 Florida Building Code unit integrity requirements for hurricane-type winds
Also Consider
Specs
System Information
view information
Stages
Single Stage
view information
TXV Required
Yes
view information
Refrigerant
R-410A
Features
view information
Low Pressure Safety Switch
No
view information
High Pressure Safety Switch
Yes
Efficiency
view information
Energy Efficiency Ratio
12.0 - 13.0 EER
view information
Energy Efficiency Ratio 2
11.7 - 12.5 EER2
view information
SEER
14.5 - 16.0 SEER
view information
SEER2
13.8 - 15.2 SEER2
Performance
view information
Total Cooling Capacity
4 Ton(s)
view information
Base Cooling Capacity
48000 BTU
view information
Compressor Type
Scroll
view information
Noise Level
73 Decibels
Electrical Information
view information
Frequency
60 Hz
view information
Voltage Phase
1
view information
Minimum Ampacity
26.2 Amps
view information
Maximum Overcurrent Protection (Breaker)
45 Amps
view information
Voltage
208 - 230 Volts
Line Set Information
view information
Liquid Line Size (OD)
3/8 Inches
view information
Suction Line Size (OD)
7/8 Inches
Product Dimensions
view information
Width
35 1/2 Inches
view information
Depth
35 1/2 Inches
view information
Height
36 1/2 Inches
view information
Pad Size
36x36 Inches
Product Weight
260 lbs
Shipping Weight
282 lbs
Warranty
view information
Compressor Warranty
10 Years With Online Registration
view information
Parts Warranty
10 Years
Certifications
view information
Qualifies for Govt. Money
No
view information
Approved for US Region(s)
North / Southeast / Southwest
view information
ENERGY STAR® Certified
Yes