105,000 BTU Gas Garage Heater, Power-Vented Unit Heater, Natural Gas or Propane (LP Kit Included)
105,000 BTU Gas Garage Heater, Power-Vented Unit Heater, Natural Gas or Propane (LP Kit Included)
Model: Sterling GG105A1NSA11
Model: Sterling GG105A1NSA11
Power vents through a wall or roof, no chimney needed
Propane conversion kit included in the box
Low-profile cabinet hangs up and out of the way
10-year heat exchanger warranty
- Contractor Referral Assistance (Not Installation Service) (Learn More)
The Sterling GG105A1NSA11 is a 105,000 BTU/h natural gas unit heater that hangs from the ceiling and blows warm air across a garage, shop or warehouse. Its fan moves 1,300 CFM, and the low-profile cabinet keeps it up and out of the way.
A built-in power venter pushes exhaust out through a 4 in. vent, horizontally through a wall or vertically through the roof, so it doesn't need a chimney. It ships set up for natural gas, with the propane conversion kit in the box.
APPLICATION FIT
Designed for: attached and detached garages, workshops, pole barns, warehouses and other non-living spaces that need fast, steady heat.
Skip it when: you need to heat living space or connect to ductwork. This is a utility heater for non-living spaces only. It also isn't meant for high-humidity spaces; Sterling builds separate agricultural units for those.
Key features
- Tubular aluminized-steel heat exchanger, covered for 10 years
- Single-orifice stainless steel burner: one burner to service and one orifice to change for gas conversion
- Direct spark ignition with an external LED for quick troubleshooting
- Vents standard combustion (room air) or separated combustion (two-pipe, outside air) without extra parts
- Add the Sterling AS-X7-5 combustion air inlet kit for a single concentric wall or roof termination
- Controls can be flipped to the left side in the field; OSHA fan guard, high-limit and air pressure switches are standard
What's in the box
- Unit heater with hanging brackets
- Flue collar (field-installed), plus a 4 in. to 5 in. reducer for separated combustion
- Natural gas to propane conversion kit
- Installation manual. The thermostat is sold separately.
Specifications
WHAT DOES INSTALLATION REQUIRE?
| Gas supply | Natural gas: 5.0–14.0 in. WC Propane after conversion: 11.0–14.0 in. WC. Install a drip leg, union and manual shut-off ahead of the heater. |
| Power | 115 V, 1-phase, 60 Hz; 6.4 A full load Wire per the National Electrical Code and local codes. |
| Thermostat | 24 V wall thermostat, sold separately Mount about 5 ft above the floor, away from drafts and direct heat. Keep it set at 50°F or higher to prevent condensation in the heat exchanger. |
| Mounting | Hangs from ceiling joists or four threaded rods Hanging brackets are included; rods and hardware are field-supplied. |
| Clearances | 1 in. top, sides, bottom and flue to combustibles Leave 18 in. on the fan and control-box sides for service access. |
| Garage height | 18 in. min. above the floor Repair garages: 8 ft min., separated combustion only. |
| Altitude | Rated to 2,000 ft as shipped Above 2,000 ft, derate input 4% per 1,000 ft; maximum 14,000 ft. |
| Installation | Qualified installer required Conversion to propane must use the factory-supplied conversion kit. |
| Approved for | Commercial, industrial and residential utility use Design certified to ANSI Z83.8 for non-living spaces attached to, adjacent to or part of a home. |
Venting
Standard combustion: one 4 in. vent, horizontal or vertical. A vertical Category I vent can run up to 40 ft equivalent length (count 5 ft for each 90° elbow), with at least 2 ft of horizontal run before the first elbow.
Separated combustion: separate 5 in. exhaust and intake pipes, each 5–30 ft equivalent length. Required in repair garages.
Concentric: the Sterling AS-X7-5 kit combines exhaust and intake into one 5 in. termination through the wall or roof. The installation manual covers termination clearances and full venting rules.
Compatible accessories
- Sterling AS-X7-5 5 in. combustion air inlet kit
- Honeywell T822K1042 single-stage, heat-only low-temperature thermostat
- DiversiTech 6-HG15 manometer, for checking supply and manifold pressure at setup
GARAGE INSTALLS
In a home garage, hang the heater at least 18 in. above the floor. In a repair garage, it must be at least 8 ft above the floor and vented as separated combustion; standard combustion is not allowed there. Do not install it in areas with corrosive, chlorinated or acidic vapors, and do not connect it to ductwork.
Enjoy free shipping on any accessories purchased with the Sterling GG105A1NSA11.


Sterling GG Series Heater Installation Instructions(PDF, 4.11 MB)
Sterling GG Series Product Data Sheet(PDF, 2.10 MB)
Sterling Gas Fired Application Manual(PDF, 5.21 MB)
Sterling GACP-23 HVAC Equipment Brochure(PDF, 7.42 MB)
Questions about this product?
Ask our specialists. Free help with sizing, setup, and everything in between.
We're closed now. Send a message and we'll reply when we open.
Mon–Fri 7am–7pm · Sat 10am–4pm · Sun 10am–3pm CT