3 Ton, 16 to18 SEER, 2-Stage Heat Pump, ComfortNET Communications System Compatible, R-410A Refrigerant
Have It Installed
Professional installation now available in !
- Free online quotes
- No home visit
HIGHLIGHTS
The Direct Comfort by Goodman® brand DC-GSZC180361 16 to 18 SEER Heat Pump uses the chlorine-free refrigerant R-410A and features energy efficiencies and operating sound levels that are among the best in the heating and cooling industry. The DC-GSZC180361 contains the two stage, high efficiency Copeland® UltraTech scroll compressor, which provides improved temperature and humidity control. This unit is designed for the consumer who desires superb comfort and quiet operation.
All Direct Comfort by Goodman 16 to 18 SEER heat pumps must be installed with a bi-flow thermostatic expansion valve. This valve is installed in front of the indoor evaporator coil inline with the line set piping.
This heat pump requires an indoor air handler or evaporator coil as part of a complete system. What tonnage coil or air handler should you use? It depends on two factors about the outside portion of the heat pump system: 1) the tonnage, and 2) the efficiency rating (listed as "SEER"). Usually, high efficiency heat pumps are required to use a larger tonnage evaporator coil than the tonnage of the outside heat pump. (For example, a 2 ton heat pump might be paired with a 3 ton or 3.5 ton evaporator coil.) To find the specific coils or air handlers that are recommended by Direct Comfort by Goodman for this heat pump, please click on the Accessories tab below.
In order to achieve the 18 SEER efficiency this heat pump must be installed with the manufacturer recommended evaporator coil, a Direct Comfort by Goodman variable speed furnace, variable speed air handler, or variable speed modular blower and thermostatic expansion valve (TXV). (See the Accessories tab above for most compatible products, or Direct Comfort by Goodman's spec sheet found under the Documents tab above to verify heat pump efficiency with particular equipment combinations.) An 18 SEER system will reduce your electric bill approximately 12% - 14% more than a 16 SEER system.
Need help putting a complete heat pump system together? Use our easy System Selector and we’ll do it for you!
If you are installing a heat pump with a backup heat source which will be a fuel furnace, you will need to install an electronic all fuel kit. This kit switches between the two heat sources as needed and prevents both the heat pump and backup heat from running at the same time. Alternatively, you can install the Honeywell VisionPro 8000 (TH8320U1008) thermostat which has the all-fuel kit functionality built into it already, in which case an external all fuel kit would not be needed.
Please note that this heat pump comes pre-charged with R-410A liquid refrigerant and by Federal law cannot be released to the atmosphere. You can purchase this equipment without being EPA certified, and if you are mechanically inclined you may perform about 90% of the equipment installation yourself. However we strongly recommend to have a professional heating/cooling contractor do the final part of the installation including managing the refrigerant. An HVAC contractor has the tools and know-how to do this work. Also, having a contractor perform the final startup and inspection of this heat pump validates your warranty with Alpine.
Standard Features:
- R-410A chlorine-free refrigerant
- Two stage Copeland UltraTech scroll compressor
- High density foam compressor sound blanket
- Copeland® ComfortAlert diagnostics
- ComfortNet™ Communications System compatible
- Low pressure switch
- Fully charged for 15' line set length
- Factory installed filter dryer
- Liquid refrigerant return protection
- Highly efficient condenser fan motor
- Copper tube / enhanced aluminum fin coil
- AHRI Certified; ETL Listed
Cabinet Features:
- Direct Comfort by Goodman® sound control top design
- Wire fan discharge grille
- Steel louver coil guard
- Baked on powder-paint finish
- Rust resistant coated screws
- Compact footprint
- Top and side maintenance access
- Single panel access to controls with space provided for field-installed accessories
- When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds
Considering purchasing a furnace, air handler, or coil with this condenser? Visit our Central Heating & Cooling Systems page to find AHRI certified systems.
Specifications
Legal Region | All |
Cooling BTUs | 35000 BTU |
Cooling Tonnage | 3 Tons |
Total Cooling Capacity | 3 Ton(s) |
Maximum Heating Output BTU | 35000 BTU |
SEER | 18 SEER |
Heating Seasonal Performance Factor | 9.5 HSPF |
Refrigerant | R-410A |
Maximum Overcurrent Protection (Breaker) | 35 Amps |
Compressor Type | Scroll UltraTech™ |
Low Pressure Safety Switch | Yes |
Liquid Line Size | 3/8 Inches |
Suction Line Size | 7/8 Inches |
TXV Required | Yes |
Noise Level | 72 Decibels |
Pad Size | 36x36 Inches |
Shipping Weight | 285 lbs |
Width | 35 1/2 Inches |
Depth | 35 1/2 Inches |
Height | 38 1/4 Inches |
Voltage | 208 / 230 Volts |
Frequency | 60 Hz |
Voltage Phase | 1 |
Compressor Warranty | Lifetime With Online Registration |
Parts Warranty | With Online Registration 10 Years |
Accessories
Documents
-
Goodman GSZC18 Brochure
(PDF, 786 KB) -
Goodman GSZC18 Installation Instructions
(PDF, 1.12 MB) -
Goodman GSXC-GSZC Warranty
(PDF, 357 KB) -
Heat Pump Wiring Diagrams
(PDF, 2.51 MB) -
GSZC18 Spec Sheet
(PDF, 3.49 MB)
Reviews
Q&A
Let's Talk